2007.03.07 Flow2 stairlift Tab 06: Systematic fault finding
www.ThyssenKruppAccessibility.nl 33
Error messages
E53 Left-handed squeeze condition Stop Low 0, 2
E54 Right-handed squeeze condition Stop Low 0, 2
E55 RF command error Switch off High 0, 2
E56 Pre-levelling timeout error Switch off High
E60 Drive motor overload Switch off High 0, 1, 2, 3, 6
E61 Level motor overload Switch off High 0, 1, 2, 3, 4, 5, 6
E62 Swivel motor overload Switch off High 0, 1, 2, 3, 4, 5, 6
E70 Swiveling outside limits Stop Low 0, 2
E71 RF error Switch off Low 0, 2
E72 Main drive brake skid error Switch off Low 0, 2
Code Comment Reset Priority Mode