Injection Molding Machine Chapter 4
V3.0
4-57
CAUTION
In semi-auto mode
,
machine stops at clamp open stop position when cycle end
,
open safety gate and take out finished product then repeat next cycle. However
,
if
the safety gate isn’t opened within the interval time
,
alarm will initiate.
4.3 Fully automatic operation
After completion of semi-auto operation
,
open front operator gate and proceed following fully-auto
operation procedures
:
A
) Press fully automatic mode key .
B
) Close all safety gate
,
press cycle start key.
C
) When cycle is completed and
INTERVAL T.
times up
,
next cycle will start again.
CAUTION
The interval time is the time duration between cycle end and starting of next cycle.
This time must be set long enough for taking products out or let it drop
,
otherwise
,
mold will be damaged.
CAUTION
When manual key is pressed
,
auto operation will be stopped immediately and the
machine is switched to manual mode.
CAUTION
During clamp close operation
,
opening safety gate will stop clamping close operation
immediately.
4.4 Emergency stop
One emergency stop push button is located on operation panel and the other one is located at the rear
operation side
,
pressing any one can shut off motor and heater immediately.
CAUTION
Don’t let mold locked over 5 minutes
,
otherwise it will be difficult to open the mold.
Rotating the emergency stop push button according to the arrow direction to release it from activated
position.
Press pump on and heater on to re-start machine.
4.5 Alarm clearance
When the alarm is activated
,
alarm red light lit and alarm buzzer sounded
,
please clear it in accordance
with the action shown on the screen
,
such as open and close operation gate once or press the alarm
reset key .
CAUTION
To clear alarm situation
,
switch operating mode to manual mode first.