Injection Molding Machine Appendix B
B-1 V2.0
APPENDIX B
Notes on Motion/ No motion
This function is for USA machine ONLY.
1 It is ONLY effective in SEMI-AUTO MODE.
2 When motion on, CLAMP OPEN, EJECTOR ADVANCE, CORE OUT are allowed with
operator gate opened after all movements in injection unit have finished.
3 EJECTOR COUNT. must be set to 1 ONLY when motion on.
4 Collapsible core mode is not allowed when motion on.
5 Starting procedures
5.1 Open operator gate.
5.2 Turn semi-auto mode on.
5.3 Turn motion key to OFF then to ON position again.
5.4 Close operator gate.
5.5 Push cycle start button to start cycle.
Remarks:
For anti tie-down safety, motion key must be turned OFF then turned ON
in semi-auto mode to activate motion function.
This procedure is only needed to do one time if machine is running in
semi-auto continuously.