Injection Molding Machine Chapter 4
V3.0
4-1
Chapter 4: Operation
1 Operation panel
1.1 Screen/function selection key
When power is turned on
,
the TMC logo will appear on the screen. Press any key to display
the maintenance checklists screen. Press the HOT key or FUNCTION key to access the
screen required by the operator.
Operator can use the HOT key on the screen to select the screen required on the operator
screen.
1.2 Number/Alphabet key
To provide function for inputting figures and alphabets
,
such function is only effective for input
on MEMORY screen.
1.3 Direction/Help key
To provide the function for cursor moving direction
,
the HELP key in the center is operation
description key
,
press once to display operation description on the current screen
,
press
again to return to the original operation screen.
1.4 Manual switch
•
Prior to operation of manual movement
,
corresponding function must be selected in the
function setting screen
,
otherwise
,
warning message will appear:
34 Function setting not selected
Select this function first.
◇
The key on the right side of operator panel is the data control switch. When it is turned to
“0”
,
all the buttons and switches on the operation panel are locked(except manual )
,
however
,
the machine can be in semi-automatic /fully automatic operation.