Overview

This document describes the TMG-GH126007, a 1260 Fabric Greenhouse manufactured by TMG Industrial.

Function Description

The TMG-GH126007 is a fabric greenhouse designed for agricultural or horticultural purposes, providing a controlled environment for plant growth. It features a robust frame structure covered with a film, and includes a roll film system for ventilation and environmental control. The structure is intended to be a permanent or semi-permanent installation, requiring careful assembly and adherence to local regulations.

Important Technical Specifications

  • Model: TMG-GH126007
  • Overall Assembled Size:
    • Length: 18.2 meters (60 feet)
    • Width: 3.66 meters (12 feet)
    • Height: 2.2 meters (7.2 feet)
  • Shoulder Height: 1.2 meters (4 feet)
  • Door Size:
    • Width: 1.2 meters (4 feet)
    • Height: 1.8 meters (6 feet)
  • Frame Components: The greenhouse frame is constructed from various tubes and plates, connected primarily with hex bolts and self-tapping screws. Key structural components include:
    • Peak arch tubes (15 units)
    • Upper rafter tubes (30 units)
    • Shoulder tubes (30 units)
    • Sidewall tubes (30 units)
    • Roof purlins (horizontal tubes) (70 units)
    • Base plates (31 units) and Door column base plates (2 units)
    • Expansion bolts M10x100mm (66 units) for securing base plates.
    • Front and Rear door cross tubes (2 units each)
    • Upper and Lower vertical tubes for rear truss (1 unit each)
    • Door frame cross pull tube (1 unit)
    • Door frame left and right tubes (1 unit each)
    • Door frame column left and right tubes (1 unit each)
    • Door horizontal tubes (4 units)
  • Covering System:
    • Film rolling machine guide tubes (2 units)
    • Roll film tubes (2 groups)
    • Film rolling machines (2 units)
    • Reed grooves (56 units) and Clip springs (56 units) for securing the film.
    • Eight clip springs (30 units)
    • Pressure film carriers (30 units)
    • Film (1 unit)
  • Fasteners:
    • Half round head bolt M6x50 (85 units)
    • Hex bolt M6x45 (132 units)
    • Hex bolt M6x80 (2 units)
    • Self tapping screw #12x25 (316 units)
    • Self tapping screw #12x35 (4 units)
    • Self tapping screw #12x35 (134 units)
  • Other Components:
    • Tube clamps (6 units)
    • Door buckle (1 unit)
    • Hex wrench (1 unit)
    • Square plugs (6 units)
    • Round plugs (6 units)
    • Braided rope (1 bundle)
    • Adhesive tape (1 volume)
    • Board (80 meters - not included in the parts list, but mentioned in installation steps)

Usage Features

  • Assembly: Requires careful reading of instructions and adherence to local safety regulations. Assembly is recommended on a day with low or no wind.
  • Foundation: Requires a solid flat level ground. Anchor bolts (6B) are used to secure base plates (6) and door column base plates (6A) to the foundation.
  • Truss System: The building comprises 15 trusses, which are assembled individually and then connected. The trusses are then erected and secured to the base plates.
  • Roof Purlins: 70 roof purlins (horizontal tubes) connect the trusses, forming the main structure.
  • Door Trusses: Dedicated front and rear door trusses are installed, incorporating door frame components and cross tubes.
  • Film Installation: The film cover is pulled over the truss frame. It must be tightened evenly to eliminate wrinkles and ensure a flat, smooth surface. Over-tightening should be avoided to prevent damage. Clip springs (22A) are used to fix the film.
  • Roll Film System: This system allows for horizontal raising and lowering of the film for ventilation. It consists of guide tubes (17), roll film tubes (18), film rolling machines (21), and pressure film carriers (24). Round plugs (32) are used on the ends of the guide tubes.
  • Door Buckle: A door buckle (20) is mounted on the door frame using self-tapping screws (29).
  • Not for Human Occupancy: The building is explicitly stated not to be intended for human occupancy.

Maintenance Features

  • Pre-Assembly Check: All components and parts must be checked against the parts list before installation to ensure completeness.
  • Structural Inspection: After assembly, a thorough inspection of the entire structure is required. All components and trusses should be squared to the baseline, and all purlins must be straight and in line.
  • Fastener Tightening: All bolts and nuts should be firmly secured, but not over-tightened, to prevent damage to the tubes.
  • Cover Protection: It is recommended to tape or add foam/rubber on the frame where joints connect and where it touches the cover. This helps extend the lifespan of the cover.
  • Post-Installation Inspection: Periodically inspect the shelter to ensure all components are firmly secured and the entire structure is well-supported. Check all bolts, nuts, and connection points.
  • Snow Removal: Immediate removal of snow from the roof is strongly recommended. Snow load should not be left on the roof overnight. A 3-foot clearance from both sides and ends of the ground must be maintained to prevent snow accumulation from pushing against the building and causing collapse.
  • No Alterations: No alterations should be made to the structure.
  • No Hanging Weights: Do not hang any weights on the frame during installation.