10/50/100/200/500/1000/2000/5000ms
35-85%RH
300/S
100/S
2
2
CI7 SERIES COUNTER
Page 02 KKCIE01-A/2-20140318
1
2
CI8-RC60
CI8-RC68
48H×96W
48H×96W
6
6
2
CI7-RC60
CI7-RC68
CI4-RC60
CI4-RC68
CI80-RC60
CI80-RC68
80H×160W
80H×160W
6
6
2
RS485
RS485
RS485
RS485
2. Model Type
NO
NO
No.
Model
Size (mm)
Display Digit
Alarm Output
Batching Output
One Relay
One Relay
One Relay
One Relay
One Relay
One Relay
Output
6
6
6
6
Relay Output
Relay Output
Relay Output
Relay Output
Relay Output
Relay Output
Relay Output
Relay Output
Communication
NO
NO
NO
NO
3. Technical Specification
One-shot Output
Series
Display
Power Supply
Fluctuation range of Allowed Voltage
Input Frequency of INA, INB
Width of Input Pulse
Input
Control Output
Contact Capacity
SSR Capacity
Data Saving Time
Power of External Sensor
Ambient Temperature
Storage Temperature
Ambient Humidity
Dielectric Strength
Dielectric
Interferance (AC Power)
Vibrate
Impact
Using Life
Mechnical
Fault
Mechnical
Fault
Mechnical
Electrical
CI
100-240V AC/DC
1Hz30Hz1KHz5KHz10KHz can be choosed
Dual Line 6 digit
90110% of
Rated Voltage (AC Power)
INA,INHIBIT,RESET,BATCH RESET,can choose 1ms or 20ms
Voltage Input: input impedance
5.4KΩ,“H”530VDC “L”:02VDC
No-voltage Input: for Short-circuit impedance is 1KΩ, Residual Voltage: Max 2V DC,
Open-circuit impedance Max 100KΩ
NO:250VAC 3A Impedance NC250VAC 2A Impedance
Max: 30VDC Max: 100mA
12VDC±10%
-10℃~50
-25℃~65
10 Years
Less than 100mA
Unfreezing State
Unfreezing State
Min: 100MΩ (at500VDC)
2000V AC 50/60Hz one minute
±2kV
Square-wave generator interference (width of pulse: 1us)
Amplitude:0.5mm Frequency: 10-55Hz X,Y,Z each direction for ten minutes
Amplitude:0.75mm Frequency: 10-55Hz X,Y,Z each direction for one hour
(about 10G) X,Y,Z each direction for three times
(about 30G) X,Y,Z each direction for three times
more than 10,000,000 times
more than 100,000 times (NO: 250V AC 3A Load NC: 250V AC 2A Load)
72Hx72W
72Hx72W
48Hx48W
48Hx48W
4. Panel Indication
PS1: Lower line displays OUT1 setting value
PS2: Lower line displays OUT2 setting value
BA.S: Upper line displays batch counting value
Lower line displays batch setting value
Reset Key
Batch setting Key
Function Key
Parameter change Key
Lock: Button lock indication
OUT1, OUT2: OUT1 or OUT2 output indication
BA.O: Batch output indication (CI4 do not with this lamp)
Page 01 KKCIE01-A/2-20140318
Features:
Counting Speed can reach 10KCPS
Free Setting Ratio 0.00001999999
Universal Input, Choose NPN or PNP
input through Software
Up to two Counting / Length Counting alarm output,
one Batch Counting alarm output;
Applicable to Light Industries, Machinery, Packing,
Food industries, etc. for control of Length and counting etc
CI Series Multi-function Counter
CI Series Multi-function Counter User Manual
S
For your safty, please read following content carefully before you are using our Meter!
CI□□-R C
□□
0
0: Without Communication 8: With RS485 Communication
Power Supply: Blank: 100-240V AC/DC F: 24V DC
Display Digit: 6: 6 digit
Alarm Output: C: Two Alarm
Dimension(mm):
Control Ouput: R: Relay Output
4: 48H x 48W x 94.5L 7: 72H x 72W x 94.5L
8: 48H x 96W x94.5L 80: 80H x160W x83L