19
Installation of spark plug
Tip: If there is no torque wrench when installing the spark plug, a better
estimation method is to screw it 1/4-1/2 turns by force after screwing it in place,
but the spark plug shall be screwed to specified torque as soon as possible.
2Adjustment of the carburetor
The carburetor is an important component of the engine. The adjustment shall
be carried out by a dealer with professional knowledge, professional data and
equipment, to ensure that the adjustment is proper.
3Replacement of oil
WARNING
Do not drain the oil immediately after turning off the generator.
Oil temperature is very high, when operating, take care to avoid injury.
1. Place the generator on a horizontal plane surface, start and run it for a
few minutes, to increase its temperature, and then shut down the engine
and turn the three-in-one combination switch knob to "OFF";
2. Unscrew the knob , to remove oil cover plate;
3. Unscrew oil dipstick ;
4. Place an oil pan under the engine, tilt the generator to pour out the oil;
5. Place the generator on a horizontal plane surface.
ATTENTION: When filling oil, do not tilt the generator to prevent any
damage by filling too much oil.
Spark plug torque: 12.5 N.m