12
4. Installation and Commissioning.
4.1 Installation
4.1.1 Sensor ring installation
47m
(Note: The flame torch and ignitor is not the parts of the CHC-200F)
Figure 4-1 flame cutting installation
4.2 Installation of sensor ring: According to our years practice, sensor ring should be
installed lower about 1
2mm than torch head to avoid the edge effect during cutting edge of
workpiece, and it anti-collision more effectively, as showed in Figure 4-1.
4.3 While on plasma cutting, the sensor ring shall be installed little higher than the torch head,
to avoid the effect of plasma arc voltage, and it needs a special insulation part supplied from
TOMATECH. Please inform us when order it.
4.2.2 Commissioning.
4.2.1 Test after installation
Up/Down connects with GND, motor moves up and down, firstly make sure on Manual mode,
torch up/down is same direction as Up/Down control button.