- 3 -
1. Technical specification:
A. Input voltage: DC 12 V (Mains adapter or Battery or solar panel);
B. Output voltage: 11-12 KV;
C. Transformer change the range of voltage: 110-240V AC;
D. Powered by lead-acid battery and solar panel;
E. Working length:up to 5,000 m;
F. Stored energy: 0.8-1 Joules;
G. Max output energy: 0.5 Joules;
H. Consumption: 2-3 watt;
2. Power supply
Multi power supply function make the energizer working at all kind of poor power condition, Mains
AC110-240V, Battery or Solar panel with DC12V.
Mains adaptor
AC110-240V
Using the adaptor with output DC12V
Solar panel
20-60Watt DC16-21V
(Solar controller or battery is necessary)
Battery
12V4.5-60Ah
Lead-acid or other kind of battery with voltage
more than 12V.