IMPORTANT
ELECTRICAL DATA
This generator is fitted with a sealed electrical connection socket that is compatible with the generator. If the
electrical connection socket becomes damaged it must be replaced with a complete assembly that is identical
to the original, and this must be replaced by an authorised service agent. Never connect to an external power
supply. If in doubt always consult a qualified electrician.
FUEL
ONLY USE UNLEADED 91 PETROL (ULP-91RON) - NO ETHANOL
Fuel tank capacity – 7 litres (7 L)
Use of incorrect fuel and/or oil may damage the generator and will not be covered under warranty.
Do not use E10 or any type of ethanol fuel as this will damage the generator and will not be covered under
warranty.
Do not use high octane fuels (greater than 91%) as this will damage the generator and will not be covered under
warranty.
• Ensure you use clean fresh unleaded 91 petrol (ULP) - no ethanol
• Use a clean approved container to store your unleaded petrol (ULP) in before decanting into the fuel tank.
• If contaminated (dirty) or old (stale) fuel is used any damage caused will not be covered under warranty.
OIL
CHECK DAILY - ONLY USE 4-STROKE MOTOR OIL
To operate, this generator requires oil in the sump, not supplied. If the generator does not have the correct level of
oil in the sump, it will not run, see note below.
Oil capacity – approximately five hundred millilitres (0.5 L or 500 ml)
Oil type – SAE 30W or SAE 15W-40 4-stroke motor oil. Non-detergent or 2-stroke engine oils will damage the
engine and should not be used.
• Always check oil level before using.
• Always use fresh clean oil.
• Change oil every 50 hours or every 3 months.
• If contaminated (dirty) or old (stale) oil is used any damage caused will not be covered under warranty.
NOTE: This generator is fitted with an oil cut out switch and red warning light. If the oil level is empty or low then
the generator WILL NOT start or run and the low oil light will glow when the recoil is pulled.
Always check the oil level before starting the generator.
Never check or add oil while the generator is running.