3.8.2.8 Capacitance Measuring
WARNING!
To avoid electric shock, be sure the capacitors have been discharged fully before
measuring the capacitance of a capacitor.
a. Connect the black test lead to the COM jack and the red test lead to the
jack.
b. Press LEFT / RIGHT to set the highlight cursor on the Capacitance Measuring.
c. Before connect test leads across two sides of the capacitor under
measurement, be sure that the capacitor has been discharged fully.
d. The value will be displayed on the LCD.