TOPVERT G1/H1/P1 Series
E-22
Bit 4
(b0xxxx)
0
Allow PG feed-back over
compensation while Accel.
1
Refuse PG feed-back over
compensation while Accel.
Pr2-08
Up/Down command rate
0.01
1.00Hz/msec (10
1000Hz/sec) 0.01
Pr2-09
Digital Input terminal debounce
time
0.001
30.000 Sec 0.005
Pr2-10
Polarity of Digital Input terminals
00000~007FF
h00000
(0=Close circuit enable 1=Open circuit enable)
Pr2-11
Target count value
0
65500 0
Pr2-12
Pre warn count value
0
65500 0
Pr2-13
Digital pulse output gain
1~20 1
Pr2-14
Pre-set arrival frequency 1
0.00
600.00 Hz (H1:00.0
6000.0Hz)
60.00/
50.00
Pr2-15
Pre-set arrival frequency 1
bandwidth
0.00
600.00 Hz (H1:00.0
6000.0Hz)
2.00
Pr2-16
Pre-set arrival frequency 2
0.00
600.00 Hz (H1:00.0
6000.0Hz)
60.00/
50.00
Pr2-17
Pre-set arrival frequency 2
bandwidth
0.00
600.00 Hz (H1:00.0
6000.0Hz)
2.00
Pr2-18
Polarity of Digital output
terminals
00000~0003F h00000
Pr2-19
Delay time of Digital output
terminals
0.000~60.000 Sec 0.003
Pr2-20
{Pr2-19}
Multi-Function Digital output 1-
Relay 1
0: No definition
11
Pr2-21
{Pr2-20}
Multi-Function Digital output 2 -
Relay 2
1: Drive in run
1
Pr2-22
{Pr2-21}
Multi-Function Digital output 3 -
MO1
2: Master frequency attained 1
(Both Forward and Reverse)
5
Pr2-23
{Pr2-22}
Multi-Function Digital output 4 -
MO2
3: Master frequency attained 2
(Both Forward and Reverse)
9
Pr2-24
[Multi-Function Digital output 5 -
MO3]
4: Pre-set speed attained 1
(Both Forward and Reverse)
0
Pr2-25
[Multi-Function Digital output 6 -
MO4]
5: Pre-set speed attained 1 (Forward only) 0
6: Pre-set speed attained 2
(Both Forward and Reverse)
0
7 : Pre-set speed attained 2 (Forward only)
8: Drive in decel
9: Drive ready for operate
10: Low voltage alarm (LU, LUr)
11: Fault Indication
12: Base block (B.B.) Indication
13: Zero Speed (including shutdown)
14: Zero speed (while in run)
15: Terminal count value attained
16: Pre warn count value attained
17: PLC Run running
18: PLC Run paused
19: A step of PLC Run completed
20: PLC Run completed
21: OH1 pre–warning indication
22: Dwell Accel/Decel in execution
23: External operation mode indication
24: Over-torque 1 (ot1)
25: Digital frequency output (MO2 only)
26: Software brake output (MO1 only)
27: Auxiliary Motor no. 1
28: Auxiliary Motor no. 2
29: Auxiliary Motor no. 3