EasyManua.ls Logo

Toro 07411EX - Checking the Transaxle-Fluid Level; Changing the Transaxle Fluid

Toro 07411EX
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Checkingthe
Transaxle-FluidLevel
ServiceInterval:Every100hours
FluidType:SAE80W-90(APIMT-1)orSAE80W-90
(APIGL-5)
1.Parkthemachineonalevelsurface.
2.Engagetheparkingbrake.
3.Shutofftheengineandremovethekey.
4.Removethellplugonthetransaxle(Figure59).
Note:Theuidlevelshouldbeevenwiththe
bottomofthellplug.
g035761
Figure59
1.Drainplug2.Fillplug
5.Iftheuidlevelislow,removethellplugand
addthespecieduiduntilitrunsoutofthehole
(Figure59).
6.Replacethellplugandtorqueitto20to27
N∙m(15to20ft-lb).
ChangingtheTransaxle
Fluid
ServiceInterval:Every800hours/Yearly(whichever
comesrst)
FluidType:SAE80W-90(APIMT-1)orSAE80W-90
(APIGL-5)
FluidCapacity:1.6L(1.7USqt)
1.Alignadrainpanunderthedrainplug(Figure
59).
2.Removethellplugandtheseal(Figure59).
Note:Retainthellplugandsealforinstallation
instep6.
3.Removethedrainplugandtheseal,andallow
theuidtodraincompletely(Figure59).
Note:Retainthedrainplugandsealfor
installationinstep4.
4.Installthedrainplugandseal,andtorqueitto
20to27N∙m(15to20ft-lb).
5.Fillthetransaxlewiththespecieduiduntilit
runsoutofthellhole.
6.Installthellplugandseal,andtorqueitto20to
27N∙m(15to20ft-lb).
47