EasyManua.ls Logo

Toro 74200 - Activate the Battery

Toro 74200
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Assembly
13
Activate the Battery
Bulk electrolyte with 1.260 specific gravity must be
purchased from a local battery supply outlet.
1. Remove the battery from the machine.
IMPORTANT: Be careful not to damage the
long vent tube when removing the battery
box.
POTENTIAL HAZARD
Battery electrolyte contains sulfuric acid
which is a deadly poison and it causes
severe burns.
WHAT CAN HAPPEN
If you carelessly drink electrolyte you could
die or if it gets onto your skin you will be
burned.
HOW TO AVOID THE HAZARD
Do not drink electrolyte and avoid contact
with skin, eyes or clothing. Wear safety
glasses to shield your eyes and rubber
gloves to protect your hands.
Fill the battery where clean water is always
available for flushing the skin.
Follow all instructions and comply with all
safety messages on the electrolyte container.
2. Remove filler caps from the battery. Slowly pour
electrolyte into each cell until the electrolyte
level is up to the lower part of the tube (Fig. 5).
1
2
3
m–1262
Figure 5
1. Filler caps
2. Electrolyte
3. Lower part of the tube
3. Leave the covers off and connect a 3 to 4 amp
battery charger to the battery posts (Fig. 6).
Charge the battery at a rate of 4 amperes or less
for 4 hours (12 volts).
4
1
2
3
m–1254
Figure 6
1. Positive post
2. Negative post
3. Charger red (+) wire
4. Charger black (–) wire