CHASSIS
3-163Toro GrandStand Service Manual
3
80. Secure the low-pressure return line to the “T” tting
using the hose clamp (Fig. 0615).
Fig. 0615 DSCN-1485a
Note: The opposite end of the low-pressure return
line is connected to the base of the hydraulic
reservoir (Fig. 0616).
Fig. 0616 DSCN-1489a
81. Replace tting o-rings. Install the high-pressure
hoses to the pumps in their original positions (Fig.
0617).
Fig. 0617 DSCN-0810a
82. Secure the hose routings using three cable ties (Fig.
0618).
Fig. 0618 DSCN-0689a