EasyManua.ls Logo

Toro GrandStand Series - Page 256

Toro GrandStand Series
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGINE
5-15Toro GrandStand Service Manual
5
27. While holding the engine choke control lever in the
“Open” position, pull the slack from the cable jacket
and tighten the choke cable clamp (Fig. 0891).
29. Make sure the mufer exhaust is centered in the
mufer guard assembly, then tighten all four bolts
and nuts (Fig. 0893).
Fig. 0891 IMG-0584a Fig. 0893 IMG-0589a
30. Connect the electric clutch plug to the wiring harness
connector (Fig. 0894).
Fig. 0894 IMG-0474a
28. Position the mufer guard assembly and loosely
install the four carriage bolts, two mounting guard
brackets and nuts (Fig. 0892).
Note: 60” models have a guard panel, not the two
guard mounting brackets
Fig. 0892 IMG-0586a