12
BEFORE OPERATING
CHECK HYDRAULIC SYSTEM FLUID
The hydraulic system is designed to operate on SAE 10
W-30 engine oil or, as a substitute, SAE 10 W-40
engine oil. The machine's reservoir is filled at the
factory with approximately 2.7 pints of SAE 10 W-30
engine oil. However, check level of hydraulic fluid
before engine is first started and daily thereafter.
1. Position machine on a level surface and raise
coring head to the full up position.
2. Remove dipstick cap (Fig. 7) from filler neck and
wipe it with a clean rag. Insert dipstick cap into filler
neck; then remove it and check level of fluid. If level is
not within 1/2 inch from the full mark on dipstick, add
SAE 10W-30 engine oil to raise level to full mark. Do
not overfill.
3. Install dipstick filler cap onto filler neck.
4. Run engine for approximately 1 minute, recheck
level of fluid and add oil as required.
1. Dipstick cap
Figure 7