Introduction
TheelectromagneticflowmeterusesFaraday’sLawof
electromagneticinductiontomeasuretheprocessflow.
Thedeviceconsistsoftwounits:adetector,through
which the fluid to be measured flows and in which
low-level signals proportional to flow rates are
obtained; and a converter, which supplies excitation
currenttothedetector,andamplifiesthesignalsfrom
thedetectorandthenprocessesandconvertsthesignals
intothe4–20mAdccurrentsignal orcommunication
signal. Combined with a multi-functional converter
LF620 (combined type) or LF622 (separate type)
equippedwithitsoriginalpatentednoise-suppression
circuitandadvancedalgorithms.TheGF630hasavery
hightolerancetonoise,givingtheunitaverystable
outputevenforslurryfluidmeasurement.IR(Infrared)
switchesenabletheparametersettingoftheconverter
withoutremovingthecover.Flowdirectioncanbeset
ineitherway,anditsunique128x128dotmatrixLCD
displayallowstheLCDtoberotatedelectronicallyto
90,180and270degreeswithoutopeningthecover.
TheterminalblockinLCDsidemakeeasytowirein
caseofthecombinedtype.
TheAF900hand-heldterminal(HART*
1
communicator)canbeusedtocommunicatewiththe
flowmeterfromaremoteplace.PROFIBUS-PA*
2
or
Modbus*
3
interfaceisavailableasanoption.
*1: HARTprotocol(HighwayAddressableRemoteTransducer)isacommunication
protocolforindustrialsensorsrecommendedbytheHCF(HARTCommunication
Foundation).
*2:PROFIBUSisthecommunicationprotocolforfactoryandprocessautomationthat
thePROFIBUSOrganizationrecommends.Insteadofanalogcontrolwitha
conventionalanalogsignal(4-20mA),itisfieldbuswhichdigitizesallsignals.
FlowmeterssupportPROFIBUS-PA.
*3:ModbusisthecommunicationprotocolthatModiconInc.developed.Physical
layerisRS485.
Combined type
Combined typeCombined type
Combined type
GF630/LF620
GF630/LF620GF630/LF620
GF630/LF620
GF630/LF620F
GF630/LF620FGF630/LF620F
GF630/LF620F
Separate
SeparateSeparate
Separate type
type type
type
GF632/LF622
GF632/LF622GF632/LF622
GF632/LF622
GF632/LF622F
GF632/LF622FGF632/LF622F
GF632/LF622F
Figure1.Configuration
GF630/LF600 GF632 LF602
Figure2.
Figure2. Figure2.
Figure2. GF630 Premium Value series
GF630 Premium Value seriesGF630 Premium Value series
GF630 Premium Value series
Flow
Flow Flow
Flowmeters
metersmeters
meters
Specifications
OverallSpecifications
Measurementrangeintermsofflowvelocity:
0
–
0.3
m/sto0
–10
m/s(0
–1.0
ft/sto0
–
32.8
ft/s).
0
–
0.1
m/sto0
–
0.3
m/s(0
–
0.3
ft/sto0
–
1.0
ft/s)
rangeisavailableoptionallyformetersize1/2”to
18”(15to450mm).
Accuracy:
<1/2"to18”(15mmto450mm)>
±
±±
±0.2%ofRate
*1.
*Thispulseoutputerrorresultisestablishedunderstandard
operatingconditionsatToshiba'sadmittedflowcalibration
facility.
*Individualmetermeasurementerrormayvaryupto±0.5%of
Rateat1.64ft/s(0.5m/s)ormore.Oritmayvaryupto±0.3%
ofrate±0.039inch/s(1mm/s)at1.64ft/s(0.5m/s)orless.
*Currentoutput:plus±8µA(0.05%ofspan).
*Refertoindividualcalibrationdataforeachindividualmeter's
measurementerror.