AIR CONDITIONER (MULTI TYPE)
SERVICE MANUAL
FILE No. A10-005
This service manual provides relevant explanations about new outdoor unit (SMMS-i). Please refer to
the following service manuals for each indoor units.
Outdoor Unit
<SUPER MODULAR MULTI SYSTEM-i>
Model name:
<Heat Pump Model>
<Cooling Only Model>
4-way Air Discharge Cassette Type
(MMU-AP 2H)
A08-004
Compact 4-way Cassette (600 × 600) Type
(MMU-AP 1MH)
A06-002
1-way Air Discharge Cassette Type SH (2 series)
(MMU-AP 2SH)
A05-007
2-way Air Discharge Cassette Type (2 series)
(MMU-AP 2WH)
A10-007
Slim Duct Type
(MMD-AP 1SPH)
A05-007
Fresh Air Intake Indoor Unit Type
(MMD-AP 1HFE)
A06-016
High-wall Type (2 series)
(MMK-AP 2H)
A05-005
High-wall Type (3 series)
(MMK-AP 3H)
SVM-09059
Other indoor units SMMS (1 series) A03-009, A03-010
MMY-MAP0804HT8(Z)(ZG)-E
MMY-MAP1004HT8(Z)(ZG)-E
MMY-MAP1204HT8(Z)(ZG)-E
MMY-MAP1404HT8(Z)(ZG)-E
MMY-MAP1604HT8(Z)(ZG)-E
MMY-MAP0804HT8(Z)(ZG)-TR
MMY-MAP1004HT8(Z)(ZG)-TR
MMY-MAP1204HT8(Z)(ZG)-TR
MMY-MAP1404HT8(Z)(ZG)-TR
MMY-MAP1604HT8(Z)(ZG)-TR
MMY-MAP0804HT8(Z)(ZG)
MMY-MAP1004HT8(Z)(ZG)
MMY-MAP1204HT8(Z)(ZG)
MMY-MAP1404HT8(Z)(ZG)
MMY-MAP1604HT8(Z)(ZG)
MMY-MAP0804HT7(Z)(ZG)
MMY-MAP1004HT7(Z)(ZG)
MMY-MAP1204HT7(Z)(ZG)
MMY-MAP1404HT7(Z)(ZG)
MMY-MAP1604HT7(Z)(ZG)
MMY-MAP0804T8(Z)(ZG)-E
MMY-MAP1004T8(Z)(ZG)-E
MMY-MAP1204T8(Z)(ZG)-E
MMY-MAP1404T8(Z)(ZG)-E
MMY-MAP1604T8(Z)(ZG)-E
MMY-MAP0804T8(Z)(ZG)
MMY-MAP1004T8(Z)(ZG)
MMY-MAP1204T8(Z)(ZG)
MMY-MAP1404T8(Z)(ZG)
MMY-MAP1604T8(Z)(ZG)
MMY-MAP0804T8-SG
MMY-MAP1004T8-SG
MMY-MAP1204T8-SG
MMY-MAP1404T8-SG
MMY-MAP1604T8-SG

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Toshiba MMY-MAP1604T8-SG and is the answer not in the manual?

Toshiba MMY-MAP1604T8-SG Specifications

General IconGeneral
BrandToshiba
ModelMMY-MAP1604T8-SG
CategoryAir Conditioner
LanguageEnglish

Summary

Wiring Diagrams

1-1. Outdoor Unit

Provides wiring diagrams for the outdoor unit.

1-2. Indoor Unit

Details wiring diagrams for various types of indoor units.

Parts Rating

2-1. Outdoor Unit (50Hz model: MMY-MAP***4HT8-E, MAP4HT8-TR, MAP4HT8, MAP4T8-SG)

Lists parts rating for 50Hz outdoor units including Heat Pump and Cooling Only models.

2-2. Outdoor Unit (60Hz model: MMY-MAP4HT7)

Lists parts rating for 60Hz outdoor units.

2-4. Outdoor Inverter (60Hz model: MMY-MAP4HT7)

Lists parts rating for 60Hz outdoor inverter units.

2-5. Indoor Unit

Lists parts rating for various indoor unit types.

2-6. Parts Layout in Outdoor Unit

Diagrams showing the layout of parts within the outdoor unit.

2-7. Parts Layout in Inverter Assembly

Diagrams showing the layout of parts within the inverter assembly.

2-8. Outdoor (Inverter) Print Circuit Board

Identification and layout of print circuit boards in the outdoor inverter unit.

Refrigerant Piping Systematic Drawing

Combined Refrigerant Piping System Schematic Diagrams

Control Outline

6 Applied Control and Functions (including Circuit Configuration)

Details on applied control functions and circuit configurations for indoor and outdoor units.

6-1. Indoor Controller Block Diagram

6-1-1. When Main (Sub) Remote Controller Connected

Block diagram for indoor unit when main/sub remote controller is connected.

6-1-2. When Wireless Remote Controller Kit Connected

Block diagram for indoor unit when wireless remote controller kit is connected.

6-1-3. When Both Main (Sub) Remote Controller and Wireless Remote Controller Kit Connected

Block diagram for indoor unit with both wired and wireless controllers connected.

6-2. Indoor Printed Circuit Board

6-3. Optional Connector Specifications of Indoor P.C. Board

6-4. Test Operation of Indoor Unit

6-5. Method to Set Indoor Unit Function DN Code

6-6. Applied Control of Indoor Unit

6-7. Applied control for Outdoor Unit

6-7-1. Outdoor Fan High Static Pressure Shift

Procedure for adjusting outdoor fan speed for high static pressure applications.

6-7-2. Priority Operation Mode Setting

Settings for switching between priority cooling and priority heating modes.

6-8. Applied Control of Outdoor Unit

6-8-1. Power peak-cut Control (Standard)

Standard procedure for limiting peak capacity of the outdoor unit.

6-8-2. Power peak-cut Control (Extended)

Extended procedure for limiting peak capacity of the outdoor unit.

6-8-3. Snowfall Fan Control

Function to control outdoor unit fan during snowfall.

6-8-4. External master ON/OFF Control

Function to start/stop the system from the outdoor unit.

6-8-5. Night operation (sound reduction) Control

Function to decrease noise levels during night or other specific times.

6-8-6. Operation Mode Selection Control

Control for selecting operation modes imposed on indoor units.

6-8-7. Error/Operation Output

Output signals for in-operation status and errors.

6-8-8. Compressor Operation Output

Output signals indicating compressor operation status.

6-8-9. Operating Rate Output

Output signals indicating the system's operation rate.

TEST OPERATION

7-1. Procedure and Summary of Test Operation

Overview and step-by-step procedure for executing a test operation.

7-2. Check Items before Test Operation (before powering-on)

Essential checks to perform on wiring and installation before powering the system on.

7-3. Check at Main Power-on

Checks to perform on indoor and outdoor units after main power is turned on.

7-4. Address Setup

Procedure for setting system addresses for indoor and outdoor units.

Troubleshooting in Test Operation

7-5-1. A Check Code Is Displayed on the Remote Controller

Troubleshooting steps when a check code appears on the remote controller.

7-5-2. Operation from the indoor remote controller is not accepted, and a check code is displayed on the 7-segment display of the interface PC board of the header unit.

Troubleshooting when operation is not accepted and a check code is shown on the header unit's 7-segment display.

Test Operation Check

7-6-1. Fan Check

Procedure for checking the fan operation of indoor units.

7-6-2. Cooling/Heating Test Operation Check

Procedure for checking cooling and heating test operations on indoor and outdoor units.

Service Support Function

7-7-1. Check Function for Connecting of Refrigerant and Control Lines

Function to check for misconnections in refrigerant and control lines.

7-7-2. Function to Start/Stop (ON/OFF) Indoor Unit from Outdoor Unit

Function to start or stop indoor units collectively or individually from outdoor unit switches.

7-7-3. Error Clearing Function

Procedures for clearing errors from the remote controller or via interface board switches.

7-7-4. Remote Controller Distinction Function

Function to distinguish connected remote controllers for refrigerant circuit systems.

7-7-5. Pulse Motor Valve (PMV) Forced Open/Close Function in Indoor Unit

Function to force open or close indoor PMV for 2 minutes using interface board switches.

7-7-6. Pulse Motor Valve (PMV) Forced Open Fully/Close fully Function in Outdoor Unit

Function to force open or close PMV1, PMV2, PMV4 in outdoor units for 2 minutes.

7-7-7. Solenoid Valve Forced Open/Close Function in Outdoor Unit

Function to force open or close each solenoid valve in the outdoor unit for checking.

7-7-8. Fan Operation Check in Outdoor Unit

Function to check outdoor fan operation and control fan speed.

7-7-9. Abnormal Outdoor Unit Discrimination Method By Fan Operating Function

Function to discriminate abnormal outdoor units by forcing fan operation.

7-7-10. Manual Adjustment Function of Outside Temperature (TO) Sensor

Function to manually fix the TO sensor value when the unit stops abnormally.

7-7-11. Monitor Function of Remote Controller Switch

Function to monitor sensor temperature or operation status via remote controller.

TROUBLESHOOTING

8-1. Overview

General introduction to troubleshooting procedures and required tools.

8-2. Troubleshooting Method

Method for identifying faults based on check codes displayed on various devices.

8-3. Troubleshooting Based on Information Displayed on Remote Controller

Troubleshooting guide based on information displayed on the remote controller.

8-5. Diagnosis procedure for each check code

Diagnostic flowcharts for various check codes.

8-6. 7-Segment Display Function

Explanation of the 7-segment display function for checking operational status.

8-7. Oil Level Judgment Display

Display and interpretation of current compressor oil level judgment results.

8-8. Leakage/Clogging of Refrigerating Cycle Circuit

List of check codes for leakage or clogging in the refrigerating cycle or oil circuit.

8-9. Sensor Characteristics

Graphs and tables showing sensor resistance characteristics.

8-10. Pressure Sensor Output Check

Procedure for checking the output voltage of Pd and Ps pressure sensors.

BACKUP OPERATION (EMERGENCY OPERATION)

9-1. Note for Backup Operation

Important notes regarding backup operation methods based on fault contents.

9-2. Compressor Backup Operation Setting

Procedure for setting compressor backup operation when a compressor fails.

9-3. Outdoor Unit Backup Operation Setting

Procedure for setting outdoor unit backup operation in multi-unit systems.

9-4. Cooling-Season Outdoor Unit Backup Operation Setting

Procedure for backup operation specifically for cooling-season failures.

OUTDOOR UNIT REFRIGERANT RECOVERY METHOD

10-1. Refrigerant Recovery from Failed Outdoor Unit (Pump-Down)

Procedure for recovering refrigerant from a failed outdoor unit using pump-down.

10-2. How to Operate System While Failed Outdoor Unit Being Repaired

Procedure to operate the system by adjusting refrigerant amount after recovery.

10-3. Work procedure after Repair

Procedure to follow after completing repair work and vacuuming.

REPLACING COMPRESSORS

11-1. Compressor Replacement Procedure (Outline)

General outline for replacing a compressor.

11-2. Replacement of Compressors

Detailed procedures for replacing compressors, including oil adjustment.

11-3. Check Procedure to Search Cause of Compressor Oil Shortage

Procedure to diagnose causes of compressor oil shortage.

P.C. BOARD EXCHANGE PROCEDURES

13-1. Replacement of Indoor P.C. Boards

Procedures for replacing indoor unit P.C. boards, including EEPROM handling.

13-2. Replacement of Outdoor P.C. Boards

List of service P.C. boards and their configurations for outdoor units.

EXPLODED DIAGRAM/PARTS PRICE LIST

SMMS-i OUTDOOR UNIT MMY-MAP0804HT8(Z)(ZG)-E, MMY-MAP1004HT8(Z)(ZG)-E, MMY-MAP1204HT8(Z)(ZG)-E

Exploded view and parts list for SMMS-i outdoor units (MAP0804, MAP1004, MAP1204) -E models.

SMMS-i INV SERVICE PARTS LIST MMY-MAP0804HT8(Z)(ZG)-E, MMY-MAP1004HT8(Z)(ZG)-E, MMY-MAP1204HT8(Z)(ZG)-E

Service parts list for SMMS-i outdoor units (MAP0804, MAP1004, MAP1204) -E models.

SMMS-i OUTDOOR UNIT MMY-MAP1404T8(Z)(ZG)-E, MMY-MAP1604T8(Z)(ZG)-E

Exploded view and parts list for SMMS-i outdoor units (MAP1404, MAP1604) -E models.

SMMS-i INV SERVICE PARTS LIST MMY-MAP1404T8(Z)(ZG)-E, MMY-MAP1604T8(Z)(ZG)-E

Service parts list for SMMS-i outdoor units (MAP1404, MAP1604) -E models.

SMMS-i OUTDOOR UNIT MMY-MAP1404HT7(Z)(ZG), MMY-MAP1604HT7(Z)(ZG)

Exploded view and parts list for SMMS-i outdoor units (MAP1404, MAP1604) -T7 models.

SMMS-i INV SERVICE PARTS LIST MMY-MAP1404HT7(Z)(ZG), MMY-MAP1604HT7(Z)(ZG)

Service parts list for SMMS-i outdoor units (MAP1404, MAP1604) -T7 models.

SMMS-i OUTDOOR UNIT MMY-MAP0804T8-SG, MMY-MAP1004T8-SG, MMY-MAP1204T8-SG

Exploded view and parts list for SMMS-i outdoor units (MAP0804, MAP1004, MAP1204) -SG models.

SMMS-i INV SERVICE PARTS LIST MMY-MAP0804T8-SG, MMY-MAP1004T8-SG, MMY-MAP1204T8-SG

Service parts list for SMMS-i outdoor units (MAP0804, MAP1004, MAP1204) -SG models.

SMMS-i OUTDOOR UNIT MMY-MAP1404HT8(Z)(ZG)-TR, MMY-MAP1604HT8(Z)(ZG)-TR

Exploded view and parts list for SMMS-i outdoor units (MAP1404, MAP1604) -TR models.

SMMS-i INV SERVICE PARTS LIST MMY-MAP1404HT8(Z)(ZG)-TR, MMY-MAP1604HT8(Z)(ZG)-TR

Service parts list for SMMS-i outdoor units (MAP1404, MAP1604) -TR models.

SMMS-i OUTDOOR UNIT MMY-MAP1404HT7(Z)(ZG), MMY-MAP1604HT7(Z)(ZG)

Exploded view and parts list for SMMS-i outdoor units (MAP1404, MAP1604) -T7 models.

SMMS-i INV SERVICE PARTS LIST MMY-MAP1404HT7(Z)(ZG), MMY-MAP1604HT7(Z)(ZG)

Service parts list for SMMS-i outdoor units (MAP1404, MAP1604) -T7 models.