– 14 –
FILE NO. SVM-04022
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13NKHD-E, RAS-10NKHD-E, RAS-07NKHD-E)
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150°C thermo fuse
2 Thermo sensor (TA-sensor) 10kΩ at 25°C
3 Switching transformer SWT-77
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
10kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600 V
8 Capacitor (C03) KHM400VSSN47M225 47μF, 400 V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K320 560 V
11 MP24Z 12VDC
12 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 12VDC
Louver motor
Relay (Fan, RY03)
Relay (Solenoide, RY04)
13
14
G5N-1A
G5N-1A
Rating 3A/AC250V, 12VDC
Rating 3A/AC250V, 12VDC
4-2. Outdoor Unit (RAS-13UAH-E3)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 − 240 V, 50Hz
1 Compressor PH170T2-4L2 Winding resistance ( ) C-R C-S
(at 20 C) 2.22 3.04
Output (Rated) 42 W, 6 poles, 1 phase, 220 − 240 V, 50Hz
2 Fan motor (for outdoor) HF-240-42A Winding resistance ( ) Red-Black White-Black
(at 20 C) 176.2 290.5
3
Running capacitor
DS451155CBPQC AC 450 V, 1.5μF
(for fan motor)
4
Running capacitor
DS371356CPNB AC 370 V, 35μF
(for compressor)
5
Overload relay
Bimetal of current cantrol :
RAT00AL
Bimetal of temperature control :
U/T : 8.6A (100°C), OPEN : 150±5°C, CLOSE : 70±11°C
OPEN : 130±5°C, CLOSE : 75±15°C
Ω
Ω
°
°