Loading...
FILE NO. SVM-04022
45 –
<Stripping length of the power cord>
Fig. 8-4-6
NOTE
Use stranded wire only.
Wire type : More than 1.5 mm
2
(H07RN-F or
245 IEC66) or 1.3 mm
2
(AWG-16)
<Taking out the power cord>
Fig. 8-4-7
Put the power supply cord through the notch.
8-4-4. Wiring connection
<How to connect the power cord>
For the air conditioner that does not have power
cord, connect a power cord to it as mentioned
below.
(1) Open the air inlet grille upward.
(2) Remove the four screws securing the front panel.
(3) Slightly open the lower part of the front panel then
pull the upper part of the front panel toward you to
remove it from the rear plate.
(4) After removing the front panel, remove the power
cord connect cover and the cord camp.
(5) Connect and secure the power supply cord and
secure the cord camp and the power connect
cover.
(6) Put the power supply cord through the notch.
(7) Be sure to smooth the notch with a file, etc.
Fig. 8-4-5
N
L
40 mm
10 mm
30 mm
10 mm
Earth line
Air Inlet grille
Front panel
Notch