21
FILE NO. SVM-04001
5-5. RAS-07UKP-ES3 / RAS-07UA-ES3
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 0.97 14.0 High 27/19 35/24
Cooling Overload 1.13 20.0 High 32/23 43/26
Low temperature 0.63 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PA79X1T-4FZ5
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
(9.52)
Packed valve
(6.35)
0.39m
(Connecting pipe)
9.52
0.49m
(Connecting pipe)
6.35
T1
P
Refrigerant
R-22 : 0.65 kg.
Evaporator
Capillary tube
1.2x650l

Table of Contents