19
FILE NO. SVM-05016
4-8. Outdoor Unit (RAS-18UA-AR4)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH340X3C-4KT1 Winding resistance () C-R C-S
(at 20°C) 1.46 2.47
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) WLF-240-42A-1 Winding resistance () Red-Black White-Black
(at 20°C) 188 289
3
Running capacitor
451155L AC 450 V, 1.5µF
(for fan motor)
4
Running capacitor
BUM44X4505B AC 440 V, 45µF
(for compressor)
5 Magnetic contactor CLK-26J 220 – 240 V, 50 Hz
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH340X3C-4KTS1 Winding resistance () C-R C-S
(at 20°C) 1.23 2.58
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) WLF-240-42B Winding resistance () Red-Black White-Black
(at 20°C) 197 255
3
Running capacitor
451205LQ AC 450 V, 2µF
(for fan motor)
4
Running capacitor
SK42CMP45U1-S AC 420 V, 45µF
(for compressor)
5 Magnetic contactor CLK-26J 220 – 240 V, 50 Hz