5-3 Head Switching Point Adjustment
1) Playback the alignment tape.
2) Press the SW703 button on Main PCB with pincers to set the adjustment mode. (See Fig. 5-2 )
3) Press the SP/LP button of remote control then adjustment is operated automatically. (See Fig. 5-1)
4) Turn the Power off.
5-4 NVRAM Option Setting
1) NVRAM Option is adjusted at production line basically.
2) In case Micom (IC601) and NVRAM (IC605 ; EEPROM) is replaced, be sure to set the corresponding ooption number of the repaired
model. (If the option is not set, the unit is not operated.)
01 02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48
49 50 51 52 53 54 55 56
57 58 59 60 61 62 63 64
65 66 67 68 69 70 71 72
CNG : OK SAVE : MENU
Fig. 5-14
01 02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48
49 50 51 52 53 54 55 56
57 58 59 60 61 62 63 64
65 66 67 68 69 70 71 72
PLEASE WAIT
Fig. 5-15
MODEL OPTION NUMBER
V-632EF 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 18, 20, 21, 25, 29, 33, 36, 38, 40, 45, 49, 51, 52, 60, 61, 62, 63, 72
<Table 5-2>
1) Press the SW703 button on Main PCB to set the adjustment mode. (See Fig. 5-2)
2) Press the MENU button on the remote control about 5 seconds then option setting display is appeared.
(See Fig. 5-14)
3) Select the option number (See Table 5-2) of corresponding model with CURSOR button on the
remote control.
4) If selecting the option number is completed, press the OK button of remote control.
(If OK button is pressed, the selected number is changes reversed color. ; See Fig. 5-14)
5) Press the MENU button of remote control again to store the option number.
(PLEASE WAIT is displayed for a second as shown Fig. 5-15 and this setting is completed.)
6) Turn the Power off.