Toshiba VF-SX User Manual

Toshiba VF-SX
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Toshiba VF-SX and is the answer not in the manual?

Toshiba VF-SX Specifications

General IconGeneral
SeriesVF-SX
Power Range0.4kW to 315kW
Control MethodV/f control, vector control
Communication OptionsRS-485
Protection FeaturesOvervoltage, undervoltage, overcurrent
Cooling Methodforced cooling
Operating Temperature-10 to +50°C
Storage Temperature-20 to +60°C
Humidity95% RH or less (non-condensing)
AltitudeUp to 1000 m

Summary

Introduction

Inspection Procedure Upon Receipt

Details the steps for inspecting the Toshiba VF-SX inverter upon delivery to ensure it is undamaged.

Proper Environment for Installation

External Views and Connection Diagrams

Connection Diagrams

Presents simplified wiring diagrams for single and three-phase power connections to the inverter.

Application Precautions

General Application Precautions

Outlines essential precautions for the proper application and operation of the inverter, including load considerations.

Wiring Guidelines and Warnings

Inverter Wiring

Provides detailed guidelines and warnings for wiring the inverter, covering power and control circuits.

Installation of a Molded Case Circuit Breaker (MCCB)

Details the procedure for installing a Molded Case Circuit Breaker (MCCB) for motor protection.

Installation of a Primary Magnetic Contactor (MC)

Explains the correct installation of a primary magnetic contactor for motor control.

Installation of an Input Reactor

Describes the installation of an input reactor to improve power factor and suppress harmonics.

Installation of an External Overload Relay

Guides on installing an external overload relay for motor protection.

Incorrect Wiring and Incorrect External Components

Highlights common errors in wiring and the use of incorrect external components.

Basic Wiring Recommendations

Offers essential recommendations for basic wiring practices to ensure safe and reliable operation.

Standard Connections

Examples of Standard Wiring

Illustrates various standard wiring configurations for different operational modes and control signals.

Terminal Functions

Details the functions of control and power circuit terminals for proper connection and operation.

Parameter Groups

Definitions of SX Drive Group Parameters

Defines the various parameter groups used to configure the SX drive's functions and settings.

Parameter Group Tables

Presents tables that categorize and list parameters within their respective groups.

Basic Operation Theory

Operation of the Touchpad Control Panel

Explains the basic operation and functions of the inverter's touchpad control panel.

Monitor Mode

Explains how to use the 'Monitor Mode' to check various operating parameters and data.

Programming Mode

Guides users on entering and using the 'Programming Mode' to adjust parameters.

Error Reset

Details the process for resetting error conditions on the inverter.

Fundamental Operation Parameters and Functions [Gr. F]

Fundamental Parameters

Lists and briefly describes the fundamental parameters for configuring the inverter's basic operation.

Terminal Selection Parameters [Gr. SE]

Protection Parameters [Gr.Pb, Pr]

Regenerative Discharge Braking Selection [Pb] and Overvoltage Limiting Action Selection [OP55]

Explains parameters for regenerative braking and overvoltage limiting.

DC Injection Braking Start-Up Frequency [dbF], Braking Voltage [dbu], and DC Injection Braking Time [dbC]

Details parameters for DC injection braking, including start-up frequency, voltage, and time.

Emergency Stop Function [E-SEP]

Explains the emergency stop function and its associated parameters.

Emergency Stop from the Touchpad

Details the procedure for activating the emergency stop function via the touchpad.

Emergency Stop using Remote Control Signals

Explains how to use remote control signals to activate the emergency stop function.

Emergency DC Injection Braking Stop Control Time [dbC]

Details the parameter for controlling the stop time during emergency DC injection braking.

Control and Communication Parameters [Gr. CC]

Meter Adjustment Parameters [Gr. rAn]

General Drive Specifications

Error Displays, Explanations, and Remedies

Inverter Trip Causes and Remedies

Lists common inverter trip causes and provides corresponding remedies for troubleshooting.

Other Common Errors and Remedies

Details other common errors encountered with the drive and their recommended solutions.

Maintenance and Inspection

Related product manuals