EasyManua.ls Logo

Toshiba TOSVERT VF-nC3

Toshiba TOSVERT VF-nC3
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IIII
1
2
3
4
5
6
7
8
9
1010
1111
1212
1313
1414
1515
1616
E6581595ԙ
Read first
I
Safety
precautions
Introduction
Contents
Connection
Operations
Setting
parameters
Main
parameters
Other
parameters
Operation
with external
signal
Monitoring the
operation status
Measures
to satisfy the
standards
Peripheral
devices
Table of
parameters
and data
Before Contacting
your Toshiba
distributor
Specifications
Inspection and
maintenance
Warranty
1717
Appendix
Disposal of the
inverter
NOTICE
1. Make sure that this instruction manual is delivered to the
end user of the inverter unit.
2. Read this manual before installing or operating the inverter
unit, and store it in a safe place for reference.
Instruction Manual
<Detailed manual>
1-phase 120V class 0.1 to 0.75kW
1-phase 240V class 0.1 to 2.2kW
3-phase 240V class 0.1 to 4kW
Industrial Inverter
For 3-phase induction motors
Instruction ManualIndustrial Inverter
TOSVERT VF-nC3
TOSHIBA INDUSTRIAL PRODUCTS
AND SYSTEMS CORPORATION
Global Business Division
580, Horikawa-cho, Saiwai-ku, Kawasaki-city,
Kanagawa 212-0013, Japan
TEL : +81-(0)44-520-0828
FAX : +81-(0)44-520-0506
For further information, please contact your nearest Toshiba Representative or Global Business Division-Producer Goods.
The data given in this manual are subject to change without notice.
TOSHIBA INTERNATIONAL CORPORATION
13131 West Little York RD., Houston,
TX 77041, U.S.A
TEL : +1-713-466-0277
FAX : +1-713-466-8773
TOSHIBA INDUSTRIAL PRODUCTS SALES
DALIAN CORPORATION
Room No.716, 7th floor,
International Commercial Mansion,
No.201,The 4th Huanghai Road (West),
Free Trade Zone,
Dalian, China
TEL : +86-411-8754-7000
FAX : +86-411-8754-7555
TOSHIBA ASIA PACIFIC PTE LTD
20 Pasir Panjang Road,#13-27/28,
Mapletree Business City,
117439,Singapore
TEL : +65-6305-5515
FAX : +65-6305-5561
TOSHIBA INTERNATIONAL CORPORATION PTY., LTD
2 Morton Street Parramatta, NSW2150, Australia
TEL : +61-(0)2-9768-6600
FAX : +61-(0)2-9890-7542
TOSHIBA CIS LIMITED LIABILITY COMPANY
Kievskaya st., entrance 7, floor 12
Moscow, 121059, Russian Federation
TEL : +7-(0)495-642-8929
FAX : +7-(0)495-642-8908
TOSHIBA INDIA PRIVATE LIMITED
3rd Floor, Building No.10, Tower B,
Phase-II, DLF Cyber City, Gurgaon-122002 India
TEL : +91-(0)124-4996600
FAX : +91-(0)124-4996623
TOSHIBA INFORMATION, INDUSTRIAL AND POWER
SYSTEMS TAIWAN CORP.
6F, No66, Sec1 Shin Sheng N.RD, Taipei, Taiwan
TEL : +886-(0)2-2581-3639
FAX : +886-(0)2-2581-3631
75984_01_VF-nC3_E_cover01-04_201408

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required

Summary

Safety Precautions

Explanation of Markings and Symbols

Explains the meaning of warning/caution markings and symbols like prohibition, instruction, and warning.

Handling and Connection Safety

Covers critical safety warnings and mandatory actions for handling, wiring, and connecting the inverter.

Installation and Operation Safety

Details safety precautions for transporting, installing, and operating the inverter, including environmental considerations.

Introduction and Product Overview

Inverter Introduction

Welcomes the user and provides context about the manual's scope and potential updates.

Names and Functions

Details the various parts and their functions of the inverter's external view and terminal boards.

Connection Procedures and Safety

Cautions on Wiring

Lists critical warnings and mandatory actions for safe and correct wiring practices.

Standard Connection Diagrams

Illustrates standard wiring diagrams for the main circuit using Sink and Source logic.

Description of Terminals

Details the functions of the power circuit and control circuit terminals.

Inverter Operations and Settings

How to Set the Setup Menu

Guides the user through setting initial parameters based on region and motor specifications.

Simplified Operation

Explains how to select operation and frequency setting methods using basic parameters.

How to operate the VF-nC3

Provides simple examples of operating the inverter using panel controls and external signals.

Parameter Setting and Adjustment

How to Set Parameters

Explains setting parameters using Easy and Standard setting modes with dial and keys.

Return to Default Settings

Details how to reset parameters to default settings or specific regional defaults.

EASY Key Function

Explains how to use the EASY key to switch between standard and easy setting modes.

Main Parameters and Functions

History Function (RUH)

Explains how to use the history function to search for recently changed parameters.

Guidance Function (RUF)

Details the guidance function for setting parameters based on specific application needs.

Setting AccelerationDeceleration Time

Covers setting acceleration and deceleration times, both automatic and manual.

Other Parameters and Control Modes

InputOutput Parameters

Details parameters related to input and output signals, including low-speed and frequency reach signals.

Selecting Control Mode

Explains how to select different V/F control modes like constant torque, vector control, and energy saving.

PWM Carrier Frequency

Explains parameters for PWM carrier frequency used for noise reduction and resonance avoidance.

Protection Functions and Alarms

Auto-Restart and Retry Functions

Explains auto-restart for momentary power failures and retry function for alarms.

Overvoltage Tripping and Supply Voltage Correction

Details parameters to prevent overvoltage tripping and adjust output voltage.

PID Control

Introduces the PID control function for process control and gain adjustments.

Troubleshooting and Maintenance

Trip Causes, Warnings, and Remedies

Lists common trip causes, error codes, descriptions, and recommended remedies.

Restoring the Inverter from a Trip

Explains how to reset the inverter after a trip, including different methods and cautions.

Inspection and Maintenance

Covers regular and periodic inspection procedures to maintain the inverter.

Specifications and Compliance

Standard Specifications

Details standard specifications like input voltage, output current, overload rating, and protective methods.

Measures to Satisfy Standards

Explains measures for complying with European EMC and low-voltage directives.

Compliance with UL Standard and CSA Standard

Covers compliance with UL and CSA standards, including general steps and installation environments.

Peripheral Devices and External Connections

Selection of Wiring Materials and Devices

Provides tables for selecting power circuit, DC reactor, and grounding cable wire sizes.

Installation of a Magnetic Contactor

Explains how to install magnetic contactors in the primary and secondary circuits.

Optional External Devices

Lists available optional external devices for the inverter.

Parameter Tables

User Parameters

Lists user parameters, including operation frequency and navigation functions.

Extended Parameters

Details extended parameters for input/output, torque boost, and protection functions.

Input Terminal Function

Details the functions that can be assigned to input terminals.

Warranty and Disposal

Warranty

Outlines the terms and conditions of the inverter's warranty.

Disposal of the Inverter

Provides safety warnings and instructions for the proper disposal of the inverter.

Appendix

KC

Information regarding the inverter's compliance with Korean radio wave laws and EMC countermeasures.