5.10 Base frequency
 : Base frequency 1
 : Base frequency voltage 1
Function
Set the base frequency and the base frequency voltage in conformance with load specifications or the
base frequency.
Note: This is an important parameter that determines the constant torque control area.
Output voltage [V]
Base frequency voltage


Output frequency (Hz)
0
[Parameter setting]
Title Function Adjustment range
Default setting

Base frequency 1 20.0-400.0 (Hz) *

Base frequency voltage1 50-330 (V) *
* Default setting values vary depending on the setup menu setting. Refer to section 11.5.