5.3 Setting acceleration/deceleration time
5.3.1 Automatic acceleration/deceleration
 Automatic acceleration/deceleration
Function
This automatically adjusts acceleration and deceleration time in line with load.
Refer to section 5.3.2 for setting acceleration/ deceleration time manually.
 =
* Adjusts the acceleration/deceleration time automatically within the range of 1/8 to 8 times as long as the time
set with the  or , depending on the current rating of the inverter.
 =
* Automatically adjusts speed during acceleration only. During deceleration, speed is not adjusted
automatically but reduced at the rate set with .
Set  (automatic acceleration/deceleration) to or .
[Parameter setting]
Title Function Adjustment range Default setting

Automatic acceleration/deceleration
0: Disabled (manual setting)
1: Automatic
2: Automatic (only at acceleration)
0
When automatically setting acceleration/deceleration time, always change the acceleration/deceleration time
so that it conforms to the load. For inverters that require a fixed acceleration/deceleration time, use the
manual settings (, ).
Setting acceleration/deceleration time (,) in conformance with mean load allows optimum setting
that conforms to further changes in load.
Use this parameter after actually connecting the motor.
When the inverter is used with a load that fluctuates considerably, it may fail to adjust the acceleration or
deceleration time in time, and therefore may be tripped.
Do not use  = when using a brake module (optional).
Output
frequency (Hz)
Deceleration
ti
Acceleration
ti

Example in case the acceleration
and deceleration time become short
Time
[]
0
Deceleration
A
cceleration

Output
frequency (Hz)
Time
[]
0
Example in case the acceleration
and deceleration time become long

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required

Related product manuals