6.9 Jump frequency - Avoiding frequency resonance
 : Jump frequency
 : Jumping width
Function
Resonance due to the natural frequency of the mechanical system can be avoided by jumping the
resonant frequency during operation. During jumping, hysteresis characteristics with respect to the jump
frequency are given to the motor.
Jump width (

)
Jump frequency (

)
Output frequency [Hz]
Frequency setting signal
0
[Parameter setting]
Title Function Adjustment range Default setting

Jump frequency 0.0-
 (Hz) 0.0

Jump width 0.0-30.0 (Hz) 0.0
Note 1: During acceleration and deceleration, the operation frequency jumps do not occur.
6.10 Preset-speed frequencies
 -  : Preset-speed frequency 8 to 15
Refer to section 3.6 for details.

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required