6.8 Time limit for lower-limit frequency operation
 : Time limit for lower-limit frequency operation
 : Hysteresis for lower-limit frequency operation
Function
If operation is carried out continuously at a frequency below the lower-limit frequency () for the period
of time set with , the inverter will automatically slow down the motor to a stop. At that time,
” is displayed (alternately) on the operation panel.
This function will be canceled if a frequency command above the lower-limit frequency () 
(Hz).
[Parameter setting]
Title Function Adjustment range Default setting

Time limit for lower-limit frequency
operation
0.0: Disabled
0.1 - 600.0 (s)
0.0

Hysteresis for lower-limit frequency
operation
0.0- (Hz) 0.2
Note: This function is valid when doing forward/reverse switching.
When starting operation, does not operate until output frequency reaches ll.
Output frequency [Hz]
+

Foward / reverse
Time [s]

ON
OFF


Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required