E6581595
D-12
4
4.4 Checking the region settings selection
 : Checking the region setting
[Parameter setting]
Title Function Adjustment range Default setting

Checking the region setting
0: Start setup menu
1: Japan (read only)
2: North America (read only)
3: Asia (read only)
4: Europe (read only)
* Default setting values vary depending on the setup menu setting. Refer to section 11.5. 1 to 4 are displayed.
Content of region settings
The number displayed when parameter  is read indicates which of the following regions was selected on
the setup menu.
:  (Japan) is selected on the setup menu.
:  (North America) is selected on the setup menu.
:  (Asia, Oceania) is selected on the setup menu.
:  (Europe) is selected on the setup menu.
The setup menu is started by writing =.
Refer to section 3.1 for details.
Note: to set to parameter  are read-only. Be aware that they cannot be written.
Function
The region selected on the setup menu can be checked.
Also, the setup menu can be started to change to a different region.

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required