[Methods of setting automatic acceleration/deceleration]
Operation panel
action
LED display Operation

Displays the output frequency.
(When standard monitor display selection = [Output frequency])

The first basic parameter ” (history function) is displayed.

Turn the setting dial to the right to change the parameter to .
Parameter values can be read by pressing the center of the setting
dial.
Turn the setting dial to the right to change the parameter to 1 or .

Press the center of the setting dial to save the changed parameter.
 and the parameter are displayed alternately.
Assigning the forced deceleration command (function number 122, 123) to any logic input terminal, it can be
changed automatic deceleration by compulsion.
5.3.2 Manually setting acceleration/deceleration time
 Acceleration time 1
 Deceleration time 1
Function
1) For acceleration time 1  programs the time that it takes for the inverter output frequency to go
from 0.0Hz to maximum frequency .
2) For deceleration time 1  programs the time that it takes for the inverter output frequency to go
from maximum frequency  to 0.0Hz.
Output frequency (Hz)



Time [sec]
O
 
(Manual)
[Parameter setting]
Title Function Adjustment range Default setting

Acceleration time 1 0.0-3000 s 10.0

Deceleration time 1 0.0-3000 s 10.0
Note: When the acceleration/deceleration time is set to 0.0 seconds, the inverter accelerates and decelerates
0.05 seconds.
MODE

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required

Related product manuals