30
Installation and Maintenance
Service Manual
As soon as the controller receives the “Turbo” instruction, the fan of the indoor unit will run at the high speed .
j. Blow
Blow Function:It is a function to automatically blow off the moist inside the exchanger of the indoor unit to
prevent mould growing after the unit is shut off.
a) On condition that this function is activated, when the “On/Off” press button is operated, the fan of the
indoor unit will still run for ten minutes (with the symbol “BLOW” displayed). At this time, the fan will stop as this
function is deactivated.
b) This function is unavailable under the AUTO, FAN, and HEAT modes.