  • A
    Angela ButlerAug 16, 2025
    What to do if my Tossi NB-P01-HB 6KW is not feeding after starting?
    • C
      Cameron CamachoAug 16, 2025
      If your Tossi Stove isn't feeding fuel after 20 seconds, it could be due to several reasons. First, the feed unit might be blocked, so check if the auger is obstructed. Second, the hopper might be empty, so fill it with fuel. Finally, there might be a connection issue between the motor and auger. Inspect the fastening screw to see if it's loose, or the auger might have jumped out.
  • D
    diana58Aug 19, 2025
    How to fix orange fire and carbon buildup in my Tossi Stove?
    • D
      Damon PerezAug 19, 2025
      If your Tossi Stove has an orange and lazy fire with piled pellets and carbon on the glass, it's likely due to a lack of air intake for burning. Clean any blockages in the gate bar. Ensure the door and window glass gasket are properly sealed. Inspect the air intake and venting pipes for blockages and clean them. If the pipes are too long, consider changing to larger diameter pipes to improve combustion.
  • C
    carlsonrobertAug 22, 2025
    Why does my Tossi NB-P01-HB 6KW fire go out and power off?
    • J
      Jessica MortonAug 22, 2025
      If your Tossi Stove's fire goes out and the power shuts off automatically, several factors could be responsible. The hopper might be empty, preventing fuel feed, or the fuel feed might be insufficient. The low-temperature switch (30°C) could be faulty. Alternatively, the set temperature might have been reached. Refill the hopper with fuel. Lower the speed of the combustion fan. Allow the stove to cool for at least an hour before restarting, or replace the low-temperature switch (30°C).
  • B
    Brenda MossAug 25, 2025
    Why Tossi NB-P01-HB 6KW Stove has no enough heat wind?
    • K
      Katelyn BurnettAug 26, 2025
      If your Tossi Stove isn't producing enough heat, it could be due to several reasons. You might be using unqualified fuel, so switch to standard pellets. The blower speed might be too low or the blower might not be running at all. Also, the heat exchange tubes or flue pass could be dirty. Clean the heat exchange tubes or flue pass. If the blower is broken, replace it, or the motherboard might be broken.
  • C
    charles47Aug 28, 2025
    What to do if Tossi NB-P01-HB 6KW fire is off because of little wood pellet?
    • J
      Jacqueline WhitneyAug 28, 2025
      If the fire in your Tossi Stove is going off due to too little wood pellet being burned, it means that the level of feeding speed is too low. Adjust the combustion fan's speed down or increase the feeding quantity.
  • T
    tstokesAug 31, 2025
    What does error "E5" mean on my Tossi NB-P01-HB 6KW Stove?
    • A
      Aaron CameronAug 31, 2025
      If your Tossi Stove is displaying "E5", it could be due to a blocked vent pipe, an open door or a seal that needs replacement, or some leakages. Shut down the stove and check the venting pipe. Close the door or change the seal. Check for any leakages and repair them. Adjust the combustion fan's speed up to offer more pressure in the stove.
  • C
    Christine MoralesSep 3, 2025
    Why does my Tossi NB-P01-HB 6KW power off after 15 minutes?
    • C
      Christopher CrawfordSep 3, 2025
      If your Tossi Stove loses power 15 minutes after ignition, it could be due to several reasons. The pellet feeder unit might be off, or the pellet supply might be too low. The 30°C temperature switch might be broken, or its connection wires might be loose. Additionally, the pressure switch in the stove could be broken. Check the pellet feeder unit and restart it. Inspect the connection wires or replace the 30°C temperature switch. Replace or repair the pressure switch.
  • K
    Katherine JamesSep 6, 2025
    Why does Tossi NB-P01-HB 6KW Stove blower keep running after it's cool?
    • J
      Jennifer JohnsonSep 6, 2025
      If the blower in your Tossi Stove continues to run even after the stove is cool and the fuel feed has stopped, it indicates that the low-temperature switch (30°C) is likely broken. Replace this switch to resolve the issue.
  • P
    Pamela BellSep 9, 2025
    What to do if Tossi Stove blower doesn’t work after pressing the start button?
    • D
      Deborah ParkerSep 9, 2025
      If the blower on your Tossi Stove isn't working after pressing the start button (or after stabilization), it could be due to a few reasons. There might be no power in the stove or control panel. Or it might be unplugged on the motherboard. The low temperature sensor could also be broken. Check the power and wires. Plug it in. Replace the low temperature sensor.
  • J
    Jennifer ChavezSep 12, 2025
    Why doesn't the start light work on my Tossi Stove?
    • D
      Darryl HerreraSep 12, 2025
      If the start light or display on your Tossi Stove isn't lighting up, it indicates there's no power in the stove or in the control panel. Check the power and wires to ensure they are properly connected.