Warmer & Cooler Commands in Auto Changeover
If the thermostat is configured to Auto
Heat/Cool changeover:
WARMER button press while in Auto or Off
mode:
When the thermostat receives a warmer command
(button press) through the remote control, and the
heater is not running, the set points will be raised
to start the heater operation. If the heater is
running upon a Warmer button press, the set points
will be raised 2 degrees.
The remote control receiver will allow up to 3
successive Warmer button presses. After the 3rd
successive Warmer button press, the IR receiver
will not accept an additional Warmer button press
for 1 minute.
When the thermostat receives a Warmer command
(button press) and the air conditioner is running, the
set points will be raised so that the Cool set point is
the same as the present room temperature which
will then turn off the air conditioner. The thermostat
will not accept another Warmer button press for 10
seconds.