1
ITEM # 52217 / MD11130
Submersible Fountain Pump
140 Gallons Per Hour
PACKAGE CONTENTS
WARNINGS AND CAUTIONS
WARNING
Risk of electrical shock. This pump is supplied with a grounding conductor and groundingtype
attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly
grounded, grounding- type receptacle.
Do not exceed the voltage shown on the pump.
Always disconnect pump from the power source before beginning any maintenance or work on the
pump.
Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if
damage is found.
Do not remove the grounding pin from the power cord plug.
To reduce the risk of electric shock, use only on portable, self-contained fountains no larger than 5 ft. in
any dimension.
Risk of electrical shock This pump has not been investigated for use in swimming pool or marine
areas.
CAUTION
This pump has been evaluated for use with fresh water only.
Use a proper power source as indicated on the pump label.
Keep the cord away from high temperatures or other heat sources.
Do not pump heated liquids.
Do not let the pump run dry. Pump must be completely submerged for proper operation and cooling.
Operate in freshwater only. Avoid heavily chlorinated water and water with high pH levels.
Do not lift the pump by its power cord.
Part
Description
Quantity
A
Pump
1
B
3/8 in. ID tubing adaptor
1
C
1/2 in. ID tubing adaptor
1
A
B
C
REMINDER
CALL 1-888-412-6001
BEFORE RETURNING TO STORE.
Question and Answer IconNeed help?

Do you have a question about the TotalPond 52217 and is the answer not in the manual?

Summary

Product Identification and Support

Product Details

Submersible Fountain Pump 140 Gallons Per Hour, Item #52217 / MD11130.

Customer Service Contact Information

Call 1-888-412-6001 or email customercare@geoglobalpartners.com for assistance.

Package Contents

Safety and Usage Warnings

Electrical Shock Hazards

Risk of electrical shock. Use only properly grounded receptacles and avoid wet areas.

General Operating Precautions

Use for fresh water only, keep cord away from heat, do not run dry, avoid high pH.

Preparation and Assembly

Assembly Time and Tools

Estimated assembly time is 5 minutes, and no tools are required for assembly.

Step 1: Connect Tubing

Connect tubing to the pump outlet with the appropriate adapter. Tubing is not included.

Step 2: Connect to Power

Place the pump in water and connect it to a proper power source, preferably GFCI.

Step 3: Adjust Flow Control

Adjust the flow control to the preferred setting for optimal pump performance.

Care and Maintenance Procedures

Regular Cleaning Schedule

Clean the pump when visibly soiled or performance drops. Always disconnect power first.

Pump Disassembly and Cleaning

Remove parts, clean with warm soapy water, and clean the impeller assembly and housing.

Troubleshooting Guide

Pump Not Operating

Check power cord, obstructions, and impeller function if the pump fails to operate.

Poor or Uneven Flow

Ensure pump is submerged, clean, and adjust flow control for satisfactory flow.

Pump Performance Specifications

Limited Warranty Details

Warranty Period and Coverage

Details warranty periods for pumps, liners, and other electrical products against defects.

Application and Usage Limitations

Warranty applies to fresh water; other liquid applications require written approval.

How to Make a Warranty Claim

Claims require calling customer service for authorization and proof of purchase.

Disclaimer and Liability Limitations

Limits liability, excludes implied warranties, and defines user responsibility for suitability.

Overview

This document describes the TotalPond Submersible Fountain Pump, model #52217 / MD11130, which has a flow rate of 140 Gallons Per Hour (GPH).

Function Description

The TotalPond Submersible Fountain Pump is designed to circulate fresh water in portable, self-contained fountains no larger than 5 ft. in any dimension. It is intended for use in ponds or fountains to create water features. The pump is supplied with a grounding conductor and a grounding-type attachment plug to ensure electrical safety. It is crucial to connect it only to a properly grounded receptacle. The pump's operation involves drawing water and expelling it through connected tubing, with an adjustable flow control to set the desired water movement.

Important Technical Specifications

  • Model Number: #52217 / MD11130
  • Flow Rate: 140 Gallons Per Hour (GPH)
  • Power Source: Must be connected to a properly grounded, grounding-type receptacle. The voltage should not exceed the voltage shown on the pump.
  • Tubing Adaptors: Includes a 3/8 inch ID tubing adaptor (Part B) and a 1/2 inch ID tubing adaptor (Part C). Tubing itself is NOT INCLUDED.
  • Application: Evaluated for use with fresh water only, specifically in portable, self-contained fountains up to 5 ft. in any dimension. Not investigated for use in swimming pools or marine areas.
  • Warranty: The pump is warranted against defective material and workmanship under normal working conditions for 2 years from the date of purchase by the original purchaser.

Usage Features

  • Easy Assembly: Estimated assembly time is 5 minutes, and no tools are required.
  • Tubing Connection: The pump includes adaptors for common tubing sizes (3/8 in. ID and 1/2 in. ID) to connect to the fountain's water outlet.
  • Submersible Operation: The pump must be completely submerged in water for proper operation and cooling. Running the pump dry is prohibited.
  • Flow Control: An adjustable flow control knob (Part D, shown in replacement parts list) allows users to set the preferred water flow rate.
  • Safety Features:
    • Equipped with a grounding conductor and plug to reduce the risk of electrical shock.
    • Users are warned not to remove the grounding pin from the power cord plug.
    • Always disconnect the pump from the power source before any maintenance or work.
    • The pump should not be lifted by its power cord.
    • Avoid pumping heated liquids.
    • Operate in freshwater only; avoid heavily chlorinated water and water with high pH levels.
    • Keep the cord away from high temperatures or other heat sources.

Maintenance Features

  • Regular Cleaning: Cleaning is necessary when the pump is visibly soiled or when a drop in performance is detected.
  • Disassembly for Cleaning:
    1. Always disconnect the pump from the power source before cleaning.
    2. Remove all parts from the pump and clean them in warm, soapy water.
    3. Disassemble the pump cover and remove the impeller cover to expose the impeller assembly.
    4. Remove the impeller assembly by gently pulling on the impeller blades.
    5. Use a soft cloth or brush to clean the impeller assembly and the inside of the impeller housing.
  • Inspection: Regularly inspect the power cord for damage before installation and/or maintenance. If damage is found, the entire pump assembly should be replaced.
  • Troubleshooting: The manual provides troubleshooting steps for common issues such as the pump failing to operate or unsatisfactory performance. These steps include checking power, inspecting for kinks or obstructions, examining the impeller for damage or jams, ensuring complete submersion, and cleaning the impeller and housing.

Warranty and Support

  • Customer Service: For questions, problems, missing parts, or warranty claims, contact customer service at 1-888-412-6001 (8 a.m.-6 p.m., EST, Monday-Friday) or email customercare@geoglobalpartners.com. The website www.totalpond.com is also available.
  • Warranty Claim Process: Warranty claims require calling customer service. If an item is deemed defective, authorization will be given to return the part(s) freight pre-paid, along with proof of purchase. The manufacturer will inspect the product to determine the cause of failure.
  • Limitations: The warranty covers only properly installed and maintained units pumping fresh water in a pond or fountain. It does not cover shipping, handling, installation, or removal costs. The manufacturer's liability is limited to replacement or repair at their discretion, and they are not liable for incidental or consequential damages.

TotalPond 52217 Specifications

General IconGeneral
BrandTotalPond
Model52217
CategoryWater Pump
LanguageEnglish