Step 1. For maximum water ow,
use the largest tubing size. Trim the
tubing adapter using a hacksaw at
the location indicated.
NOTE: If you do not want to use the
largest tubing size, skip to Step 2.
Step 2. For item #52325 connect
the tubing to the outlet of the
pump. For item #52321 connect
the adapter to the pump, and
connect the tubing to the outlet
of the adapter.
NOTE: Tubing is not included.
Step 3. Place the pump inside the
pumpshield. Pull the drawstring
until the pumpshield is fully closed
around the tubing and power
cord. Tie a knot in the drawstring.
Step 4. Place the pump into the
water and connect to a properly
grounded electrical outlet.
GFCI
Outlet
OPERATION INSTRUCTIONS
1
2
3 4
Max Flow Rate 2250 GPH (at 0 ft.)
Max Pumping Height 17 ft. (at 0 GPH)
Recommended
Waterfall Height
10 ft. (at 1215 GPH)
Power Consumption 105 watts / 1.3 amps
Cord Length 16 ft.
SPECIFICATIONS
Flow Rates (GPH)
Lift (feet)
16 220
15 420
14 130 590
13 220 780
12 330 950
11 435 1,080
10 550 1,215
9 660 1,310
8 752 1,426
7 825 1,532
6 890 1,664
5 950 1,770
4 1,010 1,849
3 1,065 1,940
2 1,113 2,034
1 1,160 2,134
0 1,200 2,250
52325 52321
Pumps
PUMPSHIELD
• Clean the pumpshield and (if necessary the pump) regularly
depending upon the environment in which it is operated. A
drop in water ow is an indication that your pumpshield and/
or pump require cleaning. The pumpshield not only protects
your pump but signicantly reduces the need for pump
maintenance.
• Before cleaning, always disconnect the pump from the power
source.
• Remove any large debris from pumpshield. Use a garden
hose to rinse off any other dirt from the pumpshield.
Register your product online!
Use your smartphone camera
to scan the QR code or visit our
website totalpond.com/register
The 14 digit serial number located on the pump
___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Date of purchase:
___ /___ /___
Item number:
______
Before installing your pump please write down the following
information:
00000000000000
Pump date code:
____ /____
mm yy
MAINTENANCE & TROUBLESHOOTING
Always disconnect units from the power source before
beginning any maintenance or work on the unit
Max Flow Rate 1200 GPH (at 0 ft.)
Max Pumping Height 16 ft. (at 0 GPH)
Recommended
Waterfall Height
5 ft. (at 950 GPH)
Power Consumption 75 watts / 0.85 amps
Cord Length 16 ft.
1200 GPH Waterfall Pump (#52325)
2000 GPH Waterfall Pump (#52321)