2.5 Manual Start
If you don't need ATS system to work automatically, please put the switch to "MANUAL"
position.
2.6 Automatic Air Damper Control
If generator have air damper control, when generator start, ATS system will automatically
open it and close it after generator start successfully.
3. BATTERY MAINTENANCE
ATS system will charge the battery automatically, the charge current is 2A.
4. NOTICE
ATS power must be bigger than load power.
Must add an AIR-BREAKER to protect ATS system, when you connect mains power
cable to ATS box.
For the TDG12000-N generator, switch the electric door key to “OFF” position, for the
TDG7000XP e TDG8500 switch the electric door key to “ON” position.
Please run generator successfully at "OFF" position first, then you can use AUTO" for
working automatically.
Please turn air-breaker switch to "ON" position when use ATS system.
Only electrician can open box for inspection and repair, there is high voltage danger.