105
2-2. Charging
2
Plug-in hybrid system
Power indicator
Illuminates when electricity is flow-
ing to the CCID (Charging Circuit
Interrupting Device).
Charging indicator
Illuminates when charging is in
progress.
Error warning indicator
Flashes when there is an electrical
leakage or when a malfunction
occurs in the CCID (Charging Cir-
cuit Interrupting Device).
■ When a malfunction occurs during charging
The indicators on the CCID (Charging Circuit Interrupting Device)
use a combination of different statuses (not illuminated, illuminated
or flashing) to inform the user of internal malfunctions.
When the error warning indicator is illuminated or flashing, temporarily
remove the plug from the outlet and then reconnect it to check if the error
indicator turns off.
If the error warning indicator turns off, charging is now possible.
If it does not turn off, perform the correction procedure in the following
chart.
Status
Power indi-
cator
Error warning
indicator
Cause/Correction procedure
Charging sys-
tem error
Not illumi-
nated
Not illumi-
nated or illu-
minated
An electrical leakage is
detected and charging is
canceled, or there is a mal-
function in the AC charging
cable.
Consult your Toyota
dealer
Illuminated Flashes
Plug tempera-
ture detection
malfunction
Flashes Flashes
There is a malfunction in the
plug temperature detection
part.
*1
Consult your Toyota
dealer