EasyManua.ls Logo

Trade-wind VSL400 Series - User Manual

Trade-wind VSL400 Series
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PERFORMANCE · QUALITY · CUSTOMER SERVICE
REVISED: JANUARY 1, 2023
© 2 0 2 3 T R A D E - W I N D M A N U F A C T U R I N G , L L C
P R O V E R B S 2 2 : 2 9
I N S T A L L A T I O N I N S T R U C T I O N S
U S E & C A R E G U I D E
V S L 4 0 0 S E R I E S
F O R I N - L I N E / E X T E R N A L R E M O T E
These models connect to an In-Line, Roof or Wall-
Mounted Remote Blower. The blower used determines
the CFM. The Trade-Wind In-Line blowers are either 836
CFM or 1266 CFM.
Before beginning installation, please thoroughly read and
become familiar with these instructions. Installation and
service must be completed by a qualified installer. Failure to
properly install this product may void the warranty.
Installer:
Owner:
Please leave Installation Instructions with the range hood liner.
Please keep Installation Instructions for local electrical inspector’s use and for future reference.
VSL430BF
VSL436BF
VSL436-0-19BF
VSL436-0-22BF
VSL442BF
VSL442-0-19BF
VSL442-0-22BF
VSL448BF
VSL448-0-19BF
VSL448-0-22BF
VSL454BF
VSL454-0-19BF
VSL454-0-22BF
VSL460BF
VSL460-0-19BF
VSL460-0-22BF
VSL472BF
VSL472-0-19BF
VSL472-0-22BF
18"
18"
19 ¼"
22
18"
19 ¼"
22"
18"
19 ¼"
22"
18"
19 ¼"
22"
18"
19 ¼"
22"
18"
19 ¼"
22"
28 ⅜"
34 ⅜"
34 ⅜"
34 ⅜"
40 ⅜"
40 ⅜"
40 ⅜"
46 ⅜"
46 ⅜"
46 ⅜"
52 ⅜"
52 ⅜"
52 ⅜"
58 ⅜"
58 ⅜"
58 ⅜"
70 ⅜"
70 ⅜"
70 ⅜"
MODEL
FRONT TO
BACK
WIDTH CFM
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
WARNINGS:
IMPORTANT:
TIPS:
Must be followed carefully to avoid personal injury.
Must be followed carefully to avoid damage and incorrect installation.
Contains helpful information to facilitate installation.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the
manufacturer at the address or telephone number listed in the warranty.
b) Before servicing or cleaning unit, switch power off at service panel, lock service panel, and lock the service
disconnection means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
READ AND SAVE THESE INSTRUCTIONS
WARNING! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
Question and Answer IconNeed help?

Do you have a question about the Trade-wind VSL400 Series and is the answer not in the manual?

Summary

PART 1: PLANNING THE INSTALLATION

Blower & Ducting Recommendations

Guidelines on blower placement, duct silencers, and optimal ducting practices for quiet operation.

Liner Installation Preparation

Covers structural framing, backing, and cut-out requirements for the hood liner installation.

PART 2: SECURING THE LINER

Tile Backsplash Clearance

Advises on positioning the liner forward for thicker tile backsplashes to ensure filter access.

Mounting Hole Drilling

Details the process for drilling mounting holes, emphasizing tool use and secure fastening.

PART 3: ELECTRICAL CONNECTION

Electrical Safety & Compliance

Stresses power disconnection, proper grounding, and adherence to electrical codes for safe installation.

Variable Speed Wiring

Provides wiring details for connecting the liner to variable speed blowers, including color codes.

PART 4: USE AND CARE

Filter Maintenance

Explains filter removal, cleaning recommendations, and reinstallation procedures for optimal performance.

Operating Controls & Lighting

Guides on using blower speed controls and operating the integrated lighting for the hood.

ENERGY SAVING TIPS

Energy Efficiency Strategies

Offers tips for reducing energy consumption during cooking operations by minimizing air currents.

CARE AND CLEANING

Stainless Steel Surface Care

Provides guidance on cleaning stainless steel surfaces, warning against abrasive materials.

LED Light Bulb Replacement

Details the procedure for removing and replacing the unit's LED light bulbs.

WARRANTY INFORMATION

Warranty Coverage & Exclusions

Outlines the terms of the product warranty, including covered defects and excluded conditions.

Service and Support

Directs users on how to obtain service and provides contact information for support.

BEST PRACTICES VENTING INSTALLATION

Building Codes & Ductwork

Emphasizes compliance with building codes and best practices for ductwork installation.

Duct Sizing & Length Limits

Details requirements for duct pipe sizes, transitions, and maximum run lengths.

Damper Installation

Provides specific instructions and warnings regarding the installation of dampers in the ventilation system.

Roof;Wall Caps & Sizing

Covers requirements for termination caps and includes a chart for duct sizing calculations.

Trade-wind VSL400 Series Specifications

General IconGeneral
BrandTrade-wind
ModelVSL400 Series
CategoryVentilation Hood
LanguageEnglish

Related product manuals