Connect the soldering iron, install the tip, saturate the sponge, plug in the power cord, and turn on the switch.
Use the security key and UP/DOWN buttons to adjust the 100's, 10's, and 1's digits of the temperature.
Turn off power, hold UP/DOWN buttons, then turn on power to enter parameter input mode.
Use UP/DOWN buttons to switch between Celsius (1C) and Fahrenheit (1F) display units.
Adjust heater error temperature tolerance within specified ranges for °C or °F.
Calibrate tip temperature by adjusting the 'CAL' screw to match room temperature.
Select lowest required temperature, clean and tin tip, use minimal solder, and clean/tin after use.
Regularly clean tip, clean threads, avoid leaving unit on, keep sponge moist, and tin tip to reduce oxidation.
Cool iron, remove nut and holder, replace tip, clean threads, and install new tip finger tight.
Indicates an abnormality in system checks, stopping all operation.
Indicates a possible failure in the sensor or circuit, cutting off power.
Flashing display indicates tip temperature falling below heater error tolerance.