Model RTAG 225 230 285 310 340 375 400 440 460
Refrigerant R134a
Compressor
Model CHHW
(N6E2,
N6E2)
CHHW
(N6E2,
N6E2
CHHW
(N5+N5,
N6)
CHHW
(N6+N5,
N6E2)
CHHW
(N6E2+
N5,N6E2)
CHHW
(N5+N5,
N5+N5
CHHW
(N6+N5,
N6+N5)
CHHW
(N6E2+
N5,
N6E2+
N5)
CHHW
(N6E2+
N6E2;
N6E2+
N6E2)
Type Horizontal semienclosed screw compressor
Starter VFD
Circuits 2 2 2 2 2 2 2 2 2
Min load % 18% 18% 12% 12% 12% 9% 9% 9% 9%
Must hold cur-
rent(1A/1B)
A 253/- 253/- 212/201 253/201 253/201 212/201 253/201 253/201 253/253
Must hold cur-
rent(2A/2B)
A 253/- 253/- 253/- 253/- 253/- 212/201 253/201 253/201 253/253
Evaporator
Type Shell & Tube (CHIL)
gpm 511 524 664 735 764 864 926 1012 1047.6
Rating WPD psid 4.7 4.2 5.4 5.3 5.7 5.7 5.4 4.3 4.2
gpm 256 262 332 367 382 432 463 506 524
gpm 767 786 995 1102 1146 1295 1390 1518 1571
Water storage lb 263 289 265 301 301 332 369 455 578
tube size inch 6“ 8“
6“
Fan type
Quantity 12 14 14 16 16 18 18 20 28
power 1,5 1.65
Fan speed RPM 910/200 970/200
Single fan Airflow
Fan current
CFM 10036
1,5
910/200
1003611772
A
Unit Max RLA(Max Compr+Fan+Control)
Control panel 1 A 441 447
3,8 3,8
410 446 446 410 438 442 447
4.7 4.7 4.7 4.7 4.7 4.7 3.8
Control panel 2 A - - 222 222 222 410 438 442 447
Unit start up amps
Control panel 1 A 441 447 560 596 596 560 588 592 447
Control panel 2 A - - 222 222 222 560 588 592 447
Refrigerant charge
ckt 1 Lb 216 229 309 348 384 326 326 403 458
ckt 2 Lb 216 229 152 165 165 326 326 403 458
Oil charge (the oil type show on unit nameplate)
ckt 1 gal 2.1 2.1 4.2 4.2 4.2 4.2 4.2 4.2 4.2
ckt 2 gal 2.1 2.1 2.1 2.1 2.1 4.2 4.2 4.2 4.2
Dimension
Length inch 296
88.4
98,5
width inch
height inch
Shipping weight lb 12642
Operation weight
1. Date Containing: Temperature of Inlet/outlet: 54/44ºF, Ambient Temperature: 95ºF, Scaling factor: 0.001 ft² ºF h/Btu.
2. Minimum start-up / operating ambient based on a 5 mph wind across the condenser.
3. Detail components structure / location please see Dimension sector.
4. Electric type could selected according unit voltage, but the current value in table is base on 460V/60HZ/3Ph.
14 RTAG-SVX001H-EN
Note:
lb 12904
88.4
98,5
16956
17221
88.4
98,5
18470
18772
344
88.4
98.5
14134
14423
88.4
98,5
18506
18808
88.4
98,5
21410
21779
88.4
98,5
22922
23376
698
88.4
98,5
28268
28846
88.4
98.5
21080
21413
Table 2. General data — 225 - 460 Ton 460 Volt -60Hz premium seasonal efficiency (variable speed fan)
467,5
456
456
410
410
364