O 1rNANE'
Performance Data
Cooling
413"R2042A1 WITH TUD120RV5+TXH041A4 AT 1400 CFM
O.D. I.D. TOT SENS,CAP,ATENTERINGD.B.TEMP TOTAL
D,B, W,B, CAP. 72 75 78 80 KW
59 38.7 34.3 383 40.0* 46.9" 3.36
85 63 41.5 28.9 330 37,0 39.7 3,42
67 44.3 22.9 27,0 31.1 33.5 3,45
59 379 339 37.9* 39.3* 40,2" 3.81
95 63 46.6 28,5 32.6 36.6 39.3 3.88
67 45.5 22,6 26.6 30.7 33.4 3.90
63 38.3 275 315 355 38.3 4.26
105 67 41.1 21.6 256 29.7 32.4 4.32
71 43.9 15.6 19.6 237 26,4 4.38
63 36.0 264 305 345 36.4" 467
!15 67 38.7 206 246 28,7 31.4 474
71 41,4 14,6 186 22.7 25,4 4.81
CORRECTIONFACTORS"OTHERNRFLOWS (MULTIPLYOR ADDAS INDICATED)
AIRFLOW 1225 1575 AIRFLOW 1225 1575
TOTALCAP X0.98 X1.01 SENS.CAP X0.94 X1,05
4'T)'R2042A1 WITH "13JD120R9V5+TXHO54A4 AT 1400 CFM
O.D. I.D, TOT SENS,CAP.ATENTERINGD,B,TEMP TOTAL
O3. W.B. CAP. 72 75 78 80 KW
59 39.7 353 39,7 41,2' 42.1" 344
85 63 42.5 296 339 382 41,1 346
67 454 23.2 276 319 34.8 35t
59 38,8 349 39.0" 40.4* 41.3" 3.8_
95 63 416 292 33.5 37.8 40.7 393
67 44.5 22.9 272 31.5 34.4 3.97
63 39.3 28.2 32.5 36.8 39.5' 4.33
105 67 42.1 21.5 26.2 30.6 33.5 4.39
71 45.0 15,5 19.8 24.2 27.1 4.46
63 37,1 272 315 35.9 37.6* 474
116 67 39.8 209 253 29.6 32,5 4.81
71 42.5 14,6 18,9 23,2 26.1 4.86
CORRECTIONFACTORS- OTHER AIRFLOWS(MULTIPLYORADD ASINDICATED)
AIRFLOW 1225 1575 AIRFLOW 1225 1575
TOTALCAP X098 X1.01 SENS.CAP X0.94 X1.06
4TrR2042A1 WITH WF036A14 AT 1400 CFM
O.D. I.D. TOT SENS.CAP.ATENTERINGD.B,TEMP TOTAL
D,B, W.B, CAP. 72 75 78 80 KW
59 374 33,4 37,5* 38,9" 39.8" 3,67
85 63 40.! 27.8 32.0 36.2 39,0 3.70
67 43.0 21.7 25.9 30.1 32,9 3.74
59 36.6 33,0 36.8* 38.2* 39,1" 4.10
95 63 39,3 27.4 31.6 35,8 38,6 414
67 42.2 21.3 25.6 29,7 32.5 4,19
63 37.0 26,4 30.6 34,8 37.2* 4,55
105 67 39.8 20.3 245 28,7 31,5 4.60
71 42.6 141 18.3 22.5 25.3 4.66
63 34.8 25,4 29.6 33,8 35.3' 4.95
115 67 37,4 19,4 236 27.8 30.6 5.02
71 40.1 13.2 17.4 21.6 24,4 5.0g
CORREC3"IONFACTORS- OTHERAIRFLOWS(MULTIPLYORADOAS INDICATED)
AIRFLOW 1225 1575 AIRFLOW 1225 1575
TOTALCAP XO8 X1.01 SENS,CAP X6.94 X1.05
4TrR2042A1 WITH "i3NE036C14 AT 1400 CFM
O.D, I.D. TOT SENS.CAP.ATENTERWGD.B,TEMP TOTAL
D.B. W.B. CAP. 72 75 79 80 KW
59 357 32.2 35.9' 37.2' 38.1' 3.55
85 63 38.4 27.1 31.O 349 37.5 3.59
67 41.3 21.4 28.3 29.2 31.8 3.62
59 351 31.g 35.4' 36.7* 37.6' 3,97
95 63 378 26,8 30.7 34.6 372 4.01
67 40.7 21.1 25.0 289 31.5 406
63 35.7 25,8 29.8 337 35.9* 443
105 67 38.4 20,2 24.1 28,0 306 4,48
71 41.2 14.4 18.3 22.2 249 4,54
63 33.6 24.9 28,8 32.7 342" 4.84
115 67 36.2 19.2 23,1 27.0 29.6 4.90
71 38.9 13.4 17.3 21.2 23,8 4.97
CORRECTIONFACTORS- OTHERAIRFLOWS(MULTIPLYOR ADDASINDICATED)
AIRFLOW 1225 1575 AIRFLOW 1225 1575
TOTALCAP X0.98 XI.01 SENS. CAP X6.95 X1.05
4"B'R2042A1 WFFH1WE042C14 AT 1400 CFM
O,D. I.D. TOT SENS.CAP.ATENTERINGD.B. TEMP TOTAL
D.B. W.B, CAP, 72 75 78 80 KW
59 37.2 33.1 370 385* 39.4* 3,56
55 63 39.9 27,8 31.8 35,7 38,4 3.60
67 42.8 21.9 25.3 29.9 32.6 3.63
55 36.4 32.7 36.5* 37.9* 38,8" 3.99
95 63 39.2 27.4 31,4 35.4 38.1 4,03
67 42,0 21.6 25.6 29.6 32,2 4.08
63 36,9 26.4 30.4 34.4 37.0* 4.44
106 67 39.7 20.6 24.6 28.6 31.2 4,50
71 42,5 14.7 18.7 22,7 25.3 4.55
63 34.7 25,4 29.4 33.4 35.2* 4.85
115 67 37.4 19,7 23,6 276 30.3 4.92
71 40.1 13.8 17.7 217 24.4 4,99
CORRECTIONFACTORS-OTHERAIRFLOWS(MULTIPLYORADDASINDICATED)
AIRFLOW 1225 1575 AIRFLOW 1225 1575
TOTALCAP XO,98 X1.91 S_N9. CAP X0.96 X1,05
4TrR2042A1 WITH TWE048C14 AT 1600 CFM
O,D. I.D. TOT SENS.CAP.ATENTERINGD.B. TEMP TOTAL
O.B. W.B. CAP, 72 76 78 60 KW
59 38.2 35.8 38.9' 40.4' 41.3" 3,70
85 63 41.O 29,6 34.3 38.9 4! .3" 3.74
67 43.9 22.9 27.5 32.1 35.2 3.77
59 37.4 36,4 38.2* 39,7. 40.6* 4,14
95 63 40.2 29.3 33.9 38.5 40.6" 4,18
67 43.1 Z2.5 27.1 31.8 34.8 4.23
63 38.0 29.3 32.9 37,5 38.7* 4,59
105 67 40,8 21,6 26.2 30.8 33,9 4.65
71 43,6 14.7 19.3 24.0 27,0 4.70
63 35,8 27.3 31,9 36.0" 36.9* 4.99
115 67 38.5 20.6 25.2 29.8 32,9 6.06
71 41.2 13.8 18.4 23.0 26.1 5,14
CORRECTIONFACTORS- OTHERAIRFLOWS(MULTIPLYORADOASINDICATED)
AIRFLOW 1400 1800 AIRFLOW 1400 1800
TOTALCAP X0.99 X1.01 SENS,CAP )(0.94 X1,05
NOTE:ALLTABLESABOVEAREATARI RATrf_ CONDITIONSRATEDWr'RH25 FEETOF REFRIGERANTLINES
• DRYCOIL CONDITION(TOTALCAPACITY_ S_NSI_E C/_PACI_()
TOTAL C_PACFFY,COMP KW ANDAPp DEW PT AREVALIDONLY FORWET COfL ALL TEMPERATUR8SIN DEGREESF
22-172R-O1-1201 (EN) 51