EasyManua.ls Logo

Trane EDHUM120 - User Manual

Trane EDHUM120
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
18-HE134D1-1A-EN
TS-1207 09/21 Rev B
Serial Number
Install Date
Sold By
Installation & Operation Instructions
The EDHUM098 and EDHUM120 are ventilating
dehumidiers that integrate into the heating and
cooling system to provide the ultimate in comfort,
health and property protection through:
+ Dehumidication
+ Fresh Air Ventilation (Optional)
+ Air Filtration
EDHUM098/EDHUM120
18-HE134D1-1A-EN
Question and Answer IconNeed help?

Do you have a question about the Trane EDHUM120 and is the answer not in the manual?

Summary

SAFETY INSTRUCTIONS

General Safety Warnings & Precautions

Important instructions marked with symbols, failure to heed can result in injury or death.

Electrical Safety Warnings

Warning regarding 120 volts and the risk of electric shock; disconnect power before service.

Installation & Handling Precautions

Instructions for safe installation, handling heavy units, and using cut-resistant gloves.

DEHUMIDIFIER SET UP

ATTACHING DUCT COLLARS

ELECTRICAL REQUIREMENTS

Electrical Safety Warnings & Precautions

Covers warnings about remote controls, 24V terminals, screw terminals, and installation precautions.

DRAIN INSTALLATION

DUCTING TO HVAC SYSTEMS

FRESH AIR VENTILATION

Determine Ventilation Requirements

Methods to calculate minimum ventilation airflow (CFM) using ASHRAE standards.

CONTROLS

AIR FILTRATION

Filter Replacement Procedure

Step-by-step guide for changing the MERV-13 air filter, emphasizing safety and airflow direction.

SERVICE

Troubleshooting Overview

General troubleshooting guide for common symptoms like no fan/compressor or cycling issues.

Control Related Troubleshooting

Procedure to diagnose issues when the control will not activate the main unit.

Performance Related Troubleshooting

Steps to diagnose performance issues, including compressor operation and water production.

Control Power Troubleshooting

Troubleshooting steps for when the control is not powering the dehumidifier.

Refrigerant Charging Procedures

Warnings and procedures for servicing the refrigerant system, including weighing charges.

Overview

This document provides installation and operation instructions for the EDHUM098 and EDHUM120 ventilating dehumidifiers. These devices are designed to integrate into existing heating and cooling systems to enhance comfort, health, and property protection.

Function Description

The EDHUM098 and EDHUM120 are ventilating dehumidifiers that offer dedicated moisture control, fresh air mechanical ventilation, and superior air filtration. They are engineered for quiet operation and low-temperature performance, providing year-round comfort. Both models feature a horizontal configuration with an optional vertical discharge, making them suitable for installation in attics, basements, or crawl spaces. They utilize the DEH 3000/R digital control for managing outdoor air ventilation and humidity.

Important Technical Specifications

EDHUM098

  • Water Removal: 98 Pints / 12.25 Gallons
  • Efficiency: 6.1 Pints/kWh (2.95 L/kWh)
  • Blower:
    • 320 CFM @ 0.0" WG
    • 297 CFM @ 0.2" WG
    • 215 CFM @ 0.4" WG
  • Operating Temperature: 49°F Min., 95°F Max.
  • Sizing: Up to 2,300 Sq. Ft. / 23,000 Cu. Ft.
  • Power: 670 watts @ 80°F and 60% RH
  • Supply Voltage: 115 volt – 1 phase – 60 Hz
  • Current Draw: 5.9 amps
  • Power Cord: 9', 115 VAC, Ground (Plug Type B: USA, MEX, CAN, JPN)
  • Circuit Requirement: 15 Amps
  • Duct Connections: 6" Round Inlet, 10" Round Inlet, 10" Round Outlet
  • Drain Connection: 3/4" Threaded Female NPT
  • Refrigerant: R410A, 1 lb. 9 oz.
  • Unit Dimensions: 14.5"W x 19.5"H x 32.375"D
  • Unit Weight: 81 lbs.
  • Shipping Dimensions: 23"W x 30"H x 40"D
  • Shipping Weight: 95 lbs.
  • Pallet Quantity: 4 per pallet
  • UPC Number: 859029004649
  • Shipping Options: UPS and LTL

EDHUM120

  • Water Removal: 121 Pints / 15.125 Gallons
  • Efficiency: 6.1 Pints/kWh (2.95 L/kWh)
  • Blower:
    • 350 CFM @ 0.0" WG
    • 285 CFM @ 0.2" WG
    • 210 CFM @ 0.4" WG
  • Operating Temperature: 49°F Min., 95°F Max.
  • Sizing: Up to 3,000 Sq. Ft. / 30,000 Cu. Ft.
  • Power: 840 watts @ 80°F and 60% RH
  • Supply Voltage: 115 volt – 1 phase – 60 Hz
  • Current Draw: 7.3 amps
  • Power Cord: 9', 115 VAC, Ground (Plug Type B: USA, MEX, CAN, JPN)
  • Circuit Requirement: 15 Amps
  • Duct Connections: 6" Round Inlet, 10" Round Inlet, 10" Round Outlet
  • Drain Connection: 3/4" Threaded Female NPT
  • Refrigerant: R410A, 1 lb. 10 oz.
  • Unit Dimensions: 14.375"W x 21"H x 32.1875"D
  • Unit Weight: 91 lbs.
  • Shipping Dimensions: 18.5"W x 23.5"H x 40"D
  • Shipping Weight: 101 lbs.
  • Pallet Quantity: 4 per pallet
  • UPC Number: 859029004656
  • Shipping Options: LTL

Usage Features

  • Dehumidification: Both models effectively remove moisture from the air, contributing to a more comfortable indoor environment.
  • Fresh Air Ventilation (Optional): The units can be connected to an insulated duct from outside to introduce fresh make-up air. A 6" diameter duct can provide up to 75 CFM of outside air. Ventilation time and frequency can be programmed via a control.
  • Air Filtration: Equipped with a MERV-13 filter (1.75" x 14.00" x 17.50"), these dehumidifiers improve indoor air quality by capturing airborne particles.
  • Ducting Options: The back panel can be rotated for either horizontal or vertical supply air discharge, offering flexibility in installation. A short piece of flexible ducting is recommended for all connections to reduce noise and vibration. Minimum 10" diameter round or equivalent rectangular ducting is advised for lengths up to 25', and 12" for longer lengths.
  • Controls: The DEH 3000 proprietary control (sold separately) allows homeowners to monitor and control relative humidity and ventilation levels. Other thermostats compatible with the dehumidifier can also be used.
  • Low-Temperature Operation: Engineered to operate effectively in cooler conditions, providing comfort year-round.
  • Transformer Protection: Features a push-button reset for transformer protection.
  • Drainage: Requires a drain trap for proper drainage. An optional condensate pump kit is available for installations requiring lift to dispose of condensate. A secondary drain pan with a float switch is recommended if installed above a living area to prevent water damage.

Maintenance Features

  • Filter Replacement: The MERV-13 filter should be checked and replaced every three to six months to maintain dehumidifier capacity and efficiency. Operating the unit without the recommended filter voids the product warranty. Filter replacement involves pulling back a slide latch to open the filter door, removing the old filter, and inserting a new one with the airflow arrow pointing into the unit.
  • Electrical Service Access: A side panel can be removed to access electrical components for servicing.
  • Troubleshooting Guide: The manual includes a comprehensive troubleshooting section to diagnose common issues related to fan operation, compressor function, dehumidification capacity, and ventilation. It provides possible reasons for symptoms and step-by-step troubleshooting procedures, emphasizing that electrical tests should be performed by a qualified service person.
  • Circuit Breaker: A resettable circuit breaker protects the 24-volt control transformer. The reset button is located on the back of the unit.
  • Compressor Shipping Support Removal: A plastic tie wrap securing the compressor for shipping must be removed before operation to prevent excessive vibration. Plugs are provided to fill the holes after removal.
  • Refrigerant Charging: Servicing the high-pressure refrigerant system and high-voltage circuitry requires a qualified service technician due to health and safety hazards. If refrigerant is lost, the leak must be repaired, and a new charge accurately weighed in, referring to the unit nameplate for correct charge weight and refrigerant type.

Trane EDHUM120 Specifications

General IconGeneral
ModelEDHUM120
Weight99.2 lbs
Power Supply115V, 60Hz
RefrigerantR410A
Dehumidification Capacity120 Pints
Operating Temperature41°F to 95°F

Related product manuals