Performance Data
50 OAU-SVX01H-EN
Table 13. OAKE general data—cooling 22–30 tons high efficiency
22 Tons Downflow 25 Tons Downflow 30 Tons Downflow
OAKE264A OAKE300A OAKE360A
Cooling Performance
Gross Cooling Capacity, Btu
(kW)
285,822 (83.77) 328,552 (96.29) 360,016 (105.51)
Heating Performance
Gross Heating Capacity, Btu
(kW)
259,134 (75.94) 294,874 (86.42) 321,576 (94.24)
CFM
Nominal cfm/AHRI rated cfm
(m
3
/h)
2750–5500 (1619–3237) 3125–6250 (1839–3679) 3750–7500 (2207–4414)
Compressor
Number 222
Type Scroll Scroll Scroll
Outdoor Coil
Type High Performance High Performance High Performance
Tube Size—OD, in. (mm) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7)
Face Area, ft
2
(m
2
) 31 (2.88) 38 (3.53) 38 (3.53)
Rows 222
FPI 121212
Indoor Coil
Type High Performance High Performance High Performance
Tube Size—OD, in. (mm) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7)
Face Area, ft
2
(m
2
) 16 (1.49) 20 (1.86) 20 (1.86)
Rows 444
FPI 121212
Refrigerant Control TXV TXV TXV
Drain Connection Size, in.
(mm)
1 (25.4) 1 (25.4) 1 (25.4)
Outdoor Fan
Type Propeller Propeller Propeller
Number Used 3 3 3
Diameter, in. (mm) 24 (609.6) 24 (609.6) 24 (609.6)
Drive Type Direct Drive Direct Drive Direct Drive
No. Speeds 111
CFM (m
3
/h) 19,500 (11,477) 19,500 (11,477) 19,500 (11,477)
Number Motors333
Motor HP (kW), per motor 1.0 (0.75) 1.0 (0.75) 1.0 (0.75)
Motor RPM 1,140 1,140 1,140
Indoor Fan
Type Backward Inclined Backward Inclined Backward Inclined
Number Used 1 1 1
Diameter Varies Varies Varies
Drive Type Direct Drive Direct Drive Direct Drive
Number Motors111
Motor HP (kW), Standard–
Oversized
1–7.5 (0.75–5.59) 1.0–15.0 (0.75–11.19) 1.0–15.0 (0.75–11.19)
Motor RPM, Standard–
Oversized
1750–3500 1750–3500 1750–3500

Table of Contents