TPLP Pre-Assembled
Low Prole
Evaporators
Bulletin T30-TPLP-PDI-14
Part #1087152
PRODUCT DATA &
INSTALLATION
Air & Electric Defrost
Electrical: 115/1/60, 208-230/1/60, 208-230/3/60, 460/1/60
See Page 16 for details
PRODUCT SUPPORT
web: t-rp.com/tplp
email: evaps@t-rp.com
call: 1-844-893-3222 x520
scan:
Medium Temperature Applications: 35°F
Low Temperature Applications: -10°F
see page 20 for details
CONTENTS
Page
Nomenclature................................................................................................................. 2
Standard Features (All Models)...................................................................................... 2
Available Congurations................................................................................................. 3
Capacity Data................................................................................................................. 4
Electrical Data................................................................................................................. 5 - 7
Wiring Diagrams - Models with PSC motors .................................................................. 8 - 15
Wiring Diagrams - Models with EC Motors / ............................................ 16 - 19
Wiring Diagrams - Models with ......................................................................... 20 - 25
Shipping Weights............................................................................................................ 26
Dimensional Data............................................................................................................ 27
Expansion Valve Selections - Electro-Mechanical Models............................................. 28 - 29
Expansion Valve Selections - Models with ....................................................... 30
Installation Instructions................................................................................................... 31 -32
Project Information........................................................................................................... 34
Product Support Resources: Service Parts, Troubleshooting, Warranty, etc................... 35
“As Built” Service Parts.................................................................................................... Back
29/11/18
Question and Answer IconNeed help?

Do you have a question about the Trenton TPLP209MAS1 and is the answer not in the manual?

Summary

Capacity Data

Electrical Data: 115;1;60 Air Defrost

Electrical Data: 208-230;1;60 Air Defrost

Electrical Data: 460;1;60 Air Defrost

Electrical Data: 208-230 V Electric Defrost

Electrical Data: 460 V Electric Defrost

PSC Motor Wiring: 115;208-230 V Air Defrost

PSC Motor Wiring: 460 V Air Defrost

PSC Electric Defrost Wiring: 208-230 V Single

PSC Electric Defrost Wiring: 208-230 V Single Contactor

PSC Electric Defrost Wiring: 208-230 V 3-Phase Single

PSC Electric Defrost Wiring: 460 V Single

PSC Electric Defrost Wiring: 208-230 V Multi-Evap

PSC Electric Defrost Wiring: 460 V Multi-Evap

SmartSpeed Fan Motor Technology

EC SmartSpeed Wiring: 115;208-230 V Air Defrost

With Defrost Time Clock

Wiring schematic for EC SmartSpeed air defrost models that include a defrost time clock.

Without Defrost Time Clock

Wiring schematic for EC SmartSpeed air defrost models operating without a defrost time clock.

EC SmartSpeed Wiring: 208-230 V Electric Defrost

EC SmartSpeed Wiring: 208-230 V Multi-Evap

ESP+ Evaporator Control Technology

What is ESP+?

Explains the features and benefits of Trenton's ESP+ intuitive evaporator control technology.

ESP+ System Energy Savings

Details the significant energy savings achievable with ESP+ technology compared to traditional controls.

ESP+ Wiring: 115 V Air Defrost

ESP+ Wiring: 208-230 V Air Defrost

ESP+ Wiring: 208-230 V 1-3 Fan Electric Defrost

ESP+ Wiring: 208-230 V 4-5 Fan Electric Defrost

ESP+ Wiring: 208-230 V 6 Fan Electric Defrost

Dimensional Data

Installation Instructions

Piping Guidelines

Wiring Requirements

Guidelines for electrical wiring, including compliance with codes, wire sizing, and terminal identification.

System Check and Start-Up

Procedures for pre-start-up checks, system verification, and initial operation parameters.

Post Start-Up Superheat Adjustment

Guidance on checking and adjusting evaporator superheat after initial system start-up.

Product Support Resources

Troubleshooting Support

Contact details for technical assistance and troubleshooting issues with the equipment.

Service Parts Information

Resources for ordering replacement parts, including web, email, and phone contacts.

Trenton TPLP209MAS1 Specifications

General IconGeneral
ModelTPLP209MAS1
CategoryAir Handlers
Air Flow Capacity900 CFM
Phase1
Cabinet MaterialGalvanized Steel
InsulationFoil Faced