P1-ER
Pump 1 error
The system has detected no change in current when pump 1 is activated or stopped.
▪ Make sure that pump 1 is connected properly (you should hear a click when properly connected).
▪ Change the output status (on/off) of pump 1 and try all possible conditions (i.e. low, high, and stop).
▪ Reset the Spa Pack by pressing the Select button twice.
▪ If the error is not cleared, the problem is surely pump 1. It must be replaced.
▪ If pump 1 is replaced, learning mode must be performed again.
P2-ER
Pump 2 error
The system has detected no change in current when pump 2 is activated or stopped.
▪ Make sure that pump 2 is plugged in correctly (you should hear a click when properly done).
▪ Change the output status (on/off) of pump 2 and try all possible conditions (i.e. low, high, and stop).
▪ Reset the Spa Pack by pressing the Select button twice.
▪ If the error is not cleared, the problem is surely pump 2. It must be replaced.
▪ If pump 2 is replaced, the learning mode must be performed again.
P3-ER
Pump 3 error
The system has detected no change in current when pump 3 is activated or stopped.
▪ Make sure that pump 3 is plugged in correctly (you should hear a click when properly done).
▪ Change the output status (on/off) of pump 3 and try all possible conditions (i.e. low, high, and stop).
▪ Reset the Spa Pack by pressing the Select button twice.
▪ If the error is not cleared, the problem is surely pump 3. It must be replaced.
▪ If pump 3 is replaced, the learning mode must be performed again.
CP-ER
Circulation pump error
The system has detected no change in current when the circulation pump is activated or stopped.
▪ Make sure that the circulation pump is plugged in correctly (you should hear a click when properly done).
▪ Change the output status by changing the set value.
▪ Reset the Spa Pack by pressing the Select button twice.
▪ If the error is not cleared, the problem is surely the circulation pump. It must be replaced.
▪ If the circulation pump is replaced, the learning mode must be performed again.
BL-ER
Turbine error
The system has detected no change in current when the turbine is activated or stopped.
▪ Make sure that the turbine is plugged in correctly.
▪ Change the output status (on/off) of the turbine.
▪ Reset the Spa Pack.
▪ If the error is not cleared, the problem is surely the turbine. It must be replaced.
▪ If the turbine is replaced, the learning mode must be performed again.