28
Trevi Spa User Guidea
P1-ER
Pump 1 error
The system has detected no change in current when pump 1 is activated or stopped.
Make sure that pump 1 is connected properly (you should hear a click when properly connected).
Change the output status (on/off) of pump 1 and try all possible conditions (i.e. low, high, and stop).
Reset the Spa Pack by pressing the Select button twice.
If the error is not cleared, the problem is surely pump 1. It must be replaced.
If pump 1 is replaced, learning mode must be performed again.
P2-ER
Pump 2 error
The system has detected no change in current when pump 2 is activated or stopped.
Make sure that pump 2 is plugged in correctly (you should hear a click when properly done).
Change the output status (on/off) of pump 2 and try all possible conditions (i.e. low, high, and stop).
Reset the Spa Pack by pressing the Select button twice.
If the error is not cleared, the problem is surely pump 2. It must be replaced.
If pump 2 is replaced, the learning mode must be performed again.
P3-ER
Pump 3 error
The system has detected no change in current when pump 3 is activated or stopped.
Make sure that pump 3 is plugged in correctly (you should hear a click when properly done).
Change the output status (on/off) of pump 3 and try all possible conditions (i.e. low, high, and stop).
Reset the Spa Pack by pressing the Select button twice.
If the error is not cleared, the problem is surely pump 3. It must be replaced.
If pump 3 is replaced, the learning mode must be performed again.
CP-ER
Circulation pump error
The system has detected no change in current when the circulation pump is activated or stopped.
Make sure that the circulation pump is plugged in correctly (you should hear a click when properly done).
Change the output status by changing the set value.
Reset the Spa Pack by pressing the Select button twice.
If the error is not cleared, the problem is surely the circulation pump. It must be replaced.
If the circulation pump is replaced, the learning mode must be performed again.
BL-ER
Turbine error
The system has detected no change in current when the turbine is activated or stopped.
Make sure that the turbine is plugged in correctly.
Change the output status (on/off) of the turbine.
Reset the Spa Pack.
If the error is not cleared, the problem is surely the turbine. It must be replaced.
If the turbine is replaced, the learning mode must be performed again.