O3-ER
Ozonator error
The system has detected no change in current when the ozonator is activated or stopped.
Make sure that the ozonator is connected correctly.
Change the output status (on/off) of the ozonator.
Reset the Spa Pack.
If the error is not cleared, the problem is surely the ozonator. It must be replaced.
If the ozonator is replaced, the learning mode must be performed again.
A1-ER
Aux.1 error
The system has detected no change in current when Aux.1 is activated or stopped.
Make sure that the aux.1 device is connected properly.
Change the output status (on/off) the Aux.1 device.
If the error is not cleared, the problem is surely the Aux.1 device. It must be replaced.
If the Aux.1 device is replaced, the learning mode must be performed again.
A2-ER
Aux.2 error
The system has detected no change in current when Aux.2 is activated or stopped.
Make sure that Aux.2 is connected correctly.
Change the output status (on/off) of the Aux.2 device.
If the error is not cleared, the problem is surely the Aux.2 device. It must be replaced.
If Aux.2 is replaced, the learning mode must be performed again.
FN-ER
Fan error
The system has detected no change in current when the fan is activated or stopped.
Make sure that the fan is connected correctly.
Change the output status (on/off) of the fan.
Reset the
Spa Pack
.
If the error is not cleared, the problem is surely the fan. It must be replaced.
If the fan is replaced, the learning mode must be performed again.
Replace the ozonator with the fan.
FB-ER
Fibre optic error
The system has detected no change in current when the fibre optic is activated or stopped.
Make sure that the fibre optic is connected correctly.
Change the output status (on / off) of the fibre optic and try all possible conditions (high or low intensity).
Reset the
Spa Pack.
If the error is not cleared, the problem is surely the fibre optic. It must be replaced.
If the fibre optic is replaced, the learning mode must be performed again.