Heatmaker H, HP and HW
Operating, Installation
& Maintenance Instructions
TRIANCO
HEATMAKER
THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH STATE AND
LOCAL CODES BY A QUALIFIED INSTALLER.
To the Installer: After installation these instructions must be given to the homeowner or left
on or near the boiler.
To the Homeowner: This booklet contains important information that will help you in
maintaining and operating this boiler. Please retain it for future reference.
HW-M2 Series H-M2 Series HP-M2 Series
HW-M2-130 H-M2-130* HP-M2-130*
HW-M2-100 H-M2-100 HP-M2-100
HW-M2-60 H-M2-60 HP-M2-60
Integrated Hydronic Heating Hydronic Heating Only Hydronic Heating Only
and Domestic Hot Water Appliance For Natural or Propane Gas. For Natural or Propane Gas
For Natural or Propane Gas. (Wall Hung).
* Field conversion only.
Question and Answer IconNeed help?

Do you have a question about the Trianco Heatmaker HW-M2-100 and is the answer not in the manual?

Summary

INSTALLING STAINLESS STEEL HORIZONTAL; VERTICAL VENTING (NON CONCENTRIC)

CONNECTING SPECIAL GAS VENT TO HEATMAKER

Connecting the special gas vent to the unit's flue outlet.

THE DIRECT VENT KITS (PART NUMBERS 2400-326 or 2400-328)

INSTALLING DIRECT VENT KITS

Procedure for installing the direct vent kits.

AIR SOURCE FOR COMBUSTION (WHEN NOT DIRECT VENTED)

How to ensure adequate air for combustion when not using direct venting.

GAS CONNECTION TO HEATMAKER

ELECTRICAL CONNECTIONS

CHECK, TEST & START-UP

FIRING BURNER

Instructions for safely igniting and operating the burner.

CHECK LIMIT CONTROL OPERATION

Testing the operation of the unit's limit controls.

MAINTENANCE

LIGHTING AND SHUTDOWN INSTRUCTIONS

Steps for safely lighting and shutting down the unit.

MAINTENANCE

Routine care and cleaning by the owner.

ADJUSTING BURNER; INPUT

CLEANING COMBUSTION CHAMBER COIL

Steps for cleaning the combustion chamber coil.

SAFETY LIMIT SWITCH

OPERATING CONTROL

Details on the operating control and its function.

IGNITER

Information on the igniter and its replacement.

LOW LIMIT (HW-M2 Series Only)

Function and replacement of the low limit control.

BOILER CONTROL

STACK SWITCH

Information on the stack switch and its function.

DELAYED IGNITION

NOISY OPERATION

INSUFFICIENT HOT WATER (HW - M2 - Series Only)

HIGH GAS CONSUMPTION

SHORT CYCLING (H-M2, HP-M2 Series Only)

CROSS CONTAMINATION AND COMBUSTION RELATED SHORT CYCLING

LOCK OUTS

SEQUENCE OF OPERATION

GENERAL TROUBLE SHOOTING

TESTING LIMIT CIRCUIT (YOU MUST COMPLETE PAGE 26 FIRST)

RED PURGE LIGHT FLASHING (YOU MUST COMPLETE PAGE 26 FIRST)

CHECKING BLOWER (YOU MUST COMPLETE PAGE 28 FIRST)

CHECKING STACK SWITCH (YOU MUST COMPLETE PAGE 29 FIRST)

RED VALVE;FLAME LIGHT FLASHING (YOU MUST COMPLETE PAGE 26 FIRST)

CHECKING PUMP

FOR YOUR SAFETY READ BEFORE OPERATING

WHAT TO DO IF YOU SMELL GAS

Emergency procedures to follow if gas is detected.

OPERATING INSTRUCTIONS

Step-by-step guide for normal unit operation.

TO TURN OFF GAS TO APPLIANCE

Procedure for safely shutting off gas supply to the unit.

Quick Reference Trouble Shooter S9301 A CONTROL MODULE