Instinct
Control Module Replacement
1
WARNING
!
Indicates a potentially hazardous situation which,
if ignored, can result in serious injury or substan-
tial property damage.
NOTICE
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
WARNING
!
For your safety, turn off electrical power supply
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
WARNING
!
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
Instructions are for a qualified installer/ ser-
vice technician only.
Read all instructions before proceeding.
Follow instructions in proper order.
Kit Part Number Description Model
INSRKIT152 Control Module Replacement All Instincts
Each Kit Includes:
Control Module
Recommended Tools:
Phillips Head Screwdriver
2019-44 Instinct Control Module Replacement
Revised
05/24/2023
Question and Answer IconNeed help?

Do you have a question about the TriangleTube Instinct INSRKIT152 and is the answer not in the manual?

Overview

This document outlines the installation, usage, and maintenance of the Instinct Control Module Replacement, a device designed to manage and control boiler operations. The replacement kit, identified as INSRKIT152, is compatible with all Instinct models.

Function Description:

The Instinct Control Module Replacement serves as the central processing unit for the boiler system, enabling precise control over heating and domestic hot water (DHW) functions. It allows users to configure various operational parameters, ensuring efficient and safe boiler performance. The module manages ignition, pump operation, temperature settings, and error handling, acting as the brain of the boiler system. It is designed to replace an existing control module, restoring or upgrading the boiler's functionality. The device integrates with the boiler's existing components, including sensors, actuators, and user interfaces, to provide comprehensive control.

Important Technical Specifications:

The control module supports a wide range of configurable settings for both heating and DHW operations. Key parameters include:

  • Heating Settings:

    • Demand Type: Thermostat & Outdoor Curve.
    • Absolute Max CH Setpoint: Configurable from 68°F [20°C] to 188°F [87°C], with a factory default of 185°F [85°C].
    • CH1 Minimum Setpoint: Configurable from 60°F [15°C] to 188°F [87°C], with a factory default of 80°F [27°C].
    • Outdoor Curve Coldest Day: Configurable from -30°F [-34°C] to 50°F [10°C], with a factory default of 10°F [-12°C].
    • Outdoor Curve Warmest Day: Configurable from 60°F [15°C] to 78°F [25°C], with a factory default of 64°F [18°C].
    • CH2 Circuit: Enabled or Disabled.
    • CH2 Maximum Setpoint: Configurable from 60°F [15°C] to 194°F [90°C], with a factory default of 140°F [60°C].
    • CH2 Minimum Setpoint: Configurable from 60°F [15°C] to 190°F [88°C], with a factory default of 80°F [27°C].
    • Warm Weather Shutdown: Off or On.
    • Circulation Pump: Disabled or Permanent.
    • CH Post Pump Time: Configurable from 0 Minutes to 20 Minutes, with a factory default of 5 Minutes.
    • Freeze Protection: Enabled.
    • Frost Protection Setpoint: Configurable from -22°F [-30°C] to 50°F [10°C], with a factory default of -22°F [-30°C].
    • Parallel Shift Value: Configurable from 0°F [0°C] to 144°F [80°C], with a factory default of 0°F [0°C].
    • CH Call Blocking: Configurable from 0 Minutes to 30 Minutes, with a factory default of 2 Minutes.
  • DHW Settings:

    • DHW Operation: Enabled.
    • Demand Type: Thermostat.
    • DHW Boiler Setpoint: Configurable from 96°F [35°C] to 188°F [87°C], with a factory default of 168°F [76°C].
    • DHW Setpoint: Configurable from 68°F [20°C] to 168°F [75°C], with a factory default of 140°F [60°C].
    • DHW Warmstart Setpoint: Configurable from 125°F [52°C] to 140°F [60°C], with a factory default of N/A.
    • DHW Warmstart Hysteresis: Configurable from 9K to 36K, with a factory default of 30°F [17K].
    • DHW On Differential: Configurable from 4°F [2°C] to 18°F [10°C], with a factory default of 6°F [3°C].
    • DHW Storage Adder: Configurable from 10°F [5°C] to 54°F [30°C], with a factory default of 27°F [15°C].
    • DHW Post Pump Time: Configurable from 0 Minutes to 30 Minutes, with a factory default of 2 Minutes.
    • DHW Priority Timeout: Off or On.
    • DHW Priority: Enabled.
    • DHW Call Blocking: Configurable from 0 Minute to 30 Minutes, with a factory default of 1 Minute.
    • DHW to CH Call Blocking: Configurable from 0 Minute to 30 Minutes, with a factory default of 1 Minute.
    • Anti-legionella Function: Disabled or Enabled.
  • Boiler Settings:

    • Lockout Temp: Configurable from 210°F [99°C].
    • Modbus Address: 0=BCST, configurable up to 247.
    • Flex. Relay 1(CH): CH1.
    • Flex. Relay 2(DHW): DHW.
    • Flex. Relay 3(P3): CH1/CH2/DHW.
    • Flex. Relay 4(ERR): ERROR.
    • Flex. Relay 5(Flame): FLAME.
    • Flex. Relay 6(P4): CH2.
    • Error Relay: On Lockout, Blocking and Warning.
    • Pump PWM Minimum: Configurable from 1% to 100%, with a factory default of 30%.
    • Ignition Level: Varies by model.
    • Mix Zone High Limit: Configurable from 68°F [20°C] to 176°F [80°C], with a factory default of 114°F [45°C].
    • Appliance Setting: Varies by model.
    • Altitude Setting: Configurable from 0 ft to 20,000 ft, with a factory default of 0 ft.

The module also features an installer access code for secure configuration and a service menu for advanced diagnostics.

Usage Features:

The Instinct Control Module Replacement offers several user-friendly features for configuration and operation:

  • Intuitive Navigation: The module's interface allows for easy navigation through menus using LEFT, RIGHT, UP, and DOWN buttons. This enables users to select and adjust various settings.
  • Installer Access: A secure installer access code ("054") is required to modify critical settings, preventing unauthorized changes.
  • Display Settings: The module provides clear visual feedback on its display, showing current settings and operational status. Icons represent different functions like CH & DHW settings, installer access, and heating settings.
  • Parameter Adjustment: Users can adjust specific parameters by selecting them and using the UP/DOWN buttons to change values. For numerical values, the LEFT/RIGHT buttons navigate between digits.
  • Saving Settings: After making changes, users must confirm and save the new settings to ensure they are applied to the boiler's operation.
  • Error Handling: The module is designed to identify and display error codes, aiding in troubleshooting. It also includes an error relay that activates during lockout, blocking, or warning conditions.
  • Pre-programmed Defaults: The module comes with factory default settings, which can be restored if needed, simplifying initial setup or recovery from incorrect configurations.
  • Boiler Type Selection: The required code for the boiler's gas type (Natural Gas or Propane) must be entered, ensuring correct combustion parameters.
  • Appliance Code: An appliance code is used to load customized settings, streamlining the setup process for specific boiler models.

Maintenance Features:

Maintenance of the Instinct Control Module Replacement primarily involves proper installation and occasional software updates or parameter adjustments.

  • Installation: The replacement process involves carefully removing the old module and installing the new one. This includes disconnecting wiring, removing mounting screws, and securing the new module. It is crucial to ensure all Molex connectors are properly seated and secured with clips.
  • Troubleshooting: The module's error display and diagnostic capabilities assist in identifying and resolving issues. If a problem arises, the installer can access the service menu to review settings and error codes.
  • Firmware Updates: While not explicitly detailed as a user-accessible feature, control modules often support firmware updates to improve performance, add new features, or fix bugs. This would typically be performed by a qualified technician.
  • Regular Checks: Periodically checking the module's settings and ensuring they align with the boiler's operational requirements is good practice.
  • Professional Assistance: For complex issues or if unsure about any procedure, it is recommended to consult a qualified installer or service technician. Improper handling can lead to electrical shock, scalding, or damage to the boiler system.
  • Safety Warnings: The manual emphasizes critical safety warnings, including the risk of electrical shock, scalding, and property damage. Always turn off the main gas shut-off valve and disconnect power to the boiler before performing any maintenance or installation.
  • Documentation: Keeping the device manual handy is crucial for reference during installation, configuration, and troubleshooting. It contains important information on installation, operation, and maintenance procedures.

TriangleTube Instinct INSRKIT152 Specifications

General IconGeneral
BrandTriangleTube
ModelInstinct INSRKIT152
CategoryBoiler Supplies
LanguageEnglish